2017年2月12日星期日

Basic description of hot water submersible pumps

Hot water submersible pump unit (including the pump and the submersible motor composed of two parts), a pair of outlet flanges, 12 × 60 bolts 6. Or configure the corresponding outlet (to facilitate the user to install the hose installation), the use of maintenance instructions 1, 1 certificate of a packing list, wooden box packaging.
Appearance color
Common colors (when customer is not required): Phthalocyanine blue (chlorinated rubber paint) suitable for general non-corrosive water in the work of the unit spraying.
Anticorrosive coating
If used in corrosive high temperature occasions: first: can change the casting materials such as stainless steel, tin bronze, etc. Second: If the corrosion is not particularly serious can brush anti-corrosion coating epoxy finish, brush anti-corrosion coating Increase the service life of the unit.
Description:
1. Open the lower bucket.
2. Open the water hole and vent hole, with water pipes or water bottles to the water hole to add water, to the vent hole overflow water to fill.
3. Tighten the water injection hole, vent hole screw, and then install the suction bucket.
Instructions for use can refer to the QJ series submersible pump instructions.
Selection can refer to the QJ series submersible pump instructions.

Daily maintenance and inspection of hot water submersible pumps

Hot water submersible pump daily maintenance
1. Check whether the pump is running when the leakage, if the leakage should be submersible pumping maintenance department maintenance
2. Always check whether the pump impeller has dirt, foreign matter, etc. to block the water impeller or outlet
3. Check the submersible pump power wire is broken, aging, power cord copper core leakage, this situation if the power cord on the shore, you can wrap, if it is best in the water is to replace the power supply.
4. Check the pump running sound is good, if there is noise, indicating that the pump bearing damage, need to repair, refueling, replacement.
Second, Tianjin submersible pump can not be normal water supply reasons
1. Is the seal safe?
2. whether the need for water diversion work
3. Whether there is a foreign body in the gap of the outlet or impeller
4. If the reversal is reversed, replace the capacitor connection method.
Third, Tianjin submersible pump abnormal noise should be how to deal with.
1. Check the coil for damage
2. Check the bearing for damage
3. Whether the impeller is loose, grinding into the water pump low-end cover.

Application Environment and Parameter Introduction of Hot Water Submersible Pump

(A) product use and main features
QJR series of hot water submersible pump for geothermal wells, for the extraction of geothermal water. Geothermal is a cheap, clean energy, widely used in heating, medical, bathing, breeding, planting, industrial and agricultural production, entertainment services and so on.
QJR series of submersible submersible submersible submersible work, with heat, corrosion, high efficiency, energy saving, easy installation and maintenance, etc., is the replacement of geothermal water equipment.
(B) the use of conditions
1, the rated power supply voltage 380V ± 5% frequency 50Hz ± 1% of the three-phase AC power supply, the motor terminal rated voltage should be guaranteed within the allowable deviation of the rated voltage range.
2, the control cabinet must have a short circuit, lack of phase, overcurrent, overload and other basic protection, and to ensure that the installation will adjust the settings to the stability of the operation, the protection of sensitive locations, the steps are very important to be professional and technical personnel debugging correctly The
3, the motor is flushing, the motor cavity must be filled with distilled water (or clean water) before installation.
4, the pump's first impeller at least invasive water level below 3 meters, the pump unit intrusion below the hydrostatic level shall not be greater than 70 meters, the bottom of the motor from the bottom of the bottom shall not be less than 5 meters.
5, select the model when the diameter and pump models to match, avoid large diameter diameter selection of small diameter pump, which is not conducive to the motor cooling.
6, the water temperature is not higher than 120 ℃.
7, the water does not contain oil substances.
8, water salinity and water quality requirements: (the main indicators of corrosive substances)
(3) material description
1, impeller: cast iron HT200 or tin bronze (various grades) such as: ZCuSn3Zn8Pb6Ni1
2, the pump shell: cast iron HT200 or stainless steel such as: 2Gr13 .304
3, the pump shaft: cold drawn steel chrome, or stainless steel 2Gr13 (1050 ℃ quenched and tempered, reinforced torque)
4, motor seal: rubber seal O-ring; machine seal
(4) the scope of application
Applicable to enterprises and institutions such as: bath, district heating, business use of geothermal energy power generation, extraction of underground high temperature hot water, according to different diameter we have different specifications for the user to choose models. The device low noise, high efficiency and save energy.
(5) technical parameters
1, to allow the working temperature range: +5 to +105 ℃
2, solid impurity content (mass ratio) is not more than 0.01%
3, PH value (pH) 6.5-8.5
4, hydrogen sulfide content of not more than 1.5mg / L
5, chloride ion content of not more than 400mg / L
6, the unit must be completely invasive water work. Vertical use, select the model when the diameter and pump models to match, avoid large diameter diameter hole selection of small diameter pump, this is not conducive to the motor cooling.
(6) motor parameters
Diving motor cable length: 3m. Such as the user needs to extend the cable can advance call us, the submersible motor for the water lubrication, before use must be filled with clean water to the motor cavity, (Note: must be filled or will reduce the motor life) If you forget to add water motor Quickly burned out.
Motor protection class: IPX8
Electromagnetic wire with high temperature waterproof line.
Power: 380V, deviation of not more than ± 5%, frequency 50HZ, the deviation does not exceed ± 1%, if the customer needs a special voltage or special frequency need to inform us in advance.
(7) the advantages of equipment
1, in the factory's careful assembly to ensure the site quickly and reliably installed.
2, the use of single-stage impeller or multi-stage impeller series, the noise is minimal. Good temperature performance, long life
3, the unit can completely break the water work, to avoid the vacuum pump is easy to use the air is not easy to use the drawbacks.
(8) Scope of supply
Hot water submersible pump unit (including the pump and the submersible motor composed of two parts), a pair of outlet flanges, 14 × 60 bolts 8. Or configure the corresponding outlet (to facilitate the user to install the hose installation) to use a maintenance manual, a certificate of 1 copies of a packing box, wooden box packaging.

Hot springs hot water submersible pump use notes have what

Hot spring hot water submersible pump use precautions
1, before using this product, please read the instructions carefully.
2, the motor must be equipped with start-up cabinet, start the cabinet with short circuit, phase, overload and other protection functions, the unit is completed after the commissioning. Note that after the normal operation must be activated cabinet protection measures to adjust the value of the appropriate location.
3, the pump must be filled with water before the wells, add water when the pump should be placed vertically, avoid the level of placement (to prevent false water level, resulting in motor water burned).
4, the pump must be installed with the installation of pump short tube, the motor and pump body must be flexible after the joint, and then drill the top hole and tighten the top wire. To slow down when lifting (to prevent damage to the unit)
5, the diameter of the water pipe to be matched with the pump, should not be too large or too small.
6, submersible pumps in special occasions (non-deep well occasions), must be reliable grounding, pay attention to safety.
7, stop pump and pump need a certain interval (not less than 5 minutes).
8, the pump is strictly prohibited without water operation, is strictly prohibited close to the work area.
9, to prevent electric shock, maintenance or maintenance must cut off the power.
10, the group installation, when the pump into the static water level should be measured on the ground insulation resistance, its value shall not be less than 5 megohms.
11, down the cable when the cable should be firmly tied in the water pipe, and fixed in the flange trough.

2017年2月10日星期五

QS small submersible pump installation using technical support

1, after the box check QS small submersible pump nameplate model specifications are consistent with the actual use.
2, select the connection with the small submersible pump caliber to match the pipe, and then tighten the hoop.
3, choose to use the power supply voltage of 380 ± 5% volts, the power frequency should be 50 Hz.
4, with 500 V megger, measuring winding on the chassis insulation resistance of not less than 150MΩ.
5, such as the use of small submersible pumps from the power source far away (generally should not exceed 200 meters), in order to ensure QS small submersible pump pressure drop fluctuations are not too large, please refer to the table recommended by the power cable Corresponding bold, and its joints are applied with solder paste. After welding with insulating waterproof bandage (prohibited in the submersible pump water level below the wiring).
6, shall not be discharged mud, dung, sewage, dirt and other corrosive media.
7, before using the screw screw and deflated screw, the motor cavity should be filled with clean water, tighten the water screw can be used before the water.
8, QS small submersible pump in the operation may not be dehydrated operation (recommended installation of automatic water level controller) to always observe the voltage, current and pump flow, should ensure that the pump running under rated conditions.
9, QS small submersible pump in the winter when the suspension should be exhausted in the machine filled with water to prevent cracking. Placed in a place where the ventilation is dry and non-corrosive. Apply the screwdriver into the impeller once every time to prevent the pump from being embroidered

Fountain pump equipment after the completion of the debugging work

With the development of society, the fountain has become an indispensable part of urban construction, when the fountain pump equipment is installed, how should the equipment debugging work?
1. Check before power-on
Before powering the installation environment should check whether the requirements, fountain pump equipment is damaged, wiring or loose, off. Check the switch, wire diameter, connection, configuration is safe, the layout is reasonable.
2. Debugging
Debugging work, pay attention to the fountain pump is not through the inverter access to the bottom of the three-phase leakage switch, with three-phase AC direct start. If there is internal leakage, short circuit and other issues, timely treatment, troubleshooting.
3. Connect the fountain pump to the inverter. On the control panel of the inverter, the function code is set to 50Hz, and then the frequency is gradually increased from small to observe whether the inverter and fountain pump are abnormal.
4. Fountain If the water is not high, you need to re-adjust the water nozzle jet and flow, only in the device to re-set the target frequency can be.
In addition to fountain pump inspection, also need to pay attention to underwater lights debugging. Pay attention to whether the water into the water, the first to each channel lights connected to the bottom of the leakage switch, all the way to brighten the underwater lights, lights and timely replacement, and then access the light controller, fine-tune the lighting control effect.
Debugging work is correct, you can rest assured that the operation

2017年2月9日星期四

Selection principle and selection steps of fountain pump

First, the fountain pump selection principles

Fountain pump is a kind of surface wide variety of general-purpose machinery and equipment, fountain pumps are widely used in petroleum, chemical, electric power metallurgy, mining, shipbuilding, light industry, agriculture, civil and defense sectors, occupies an important national economy status. Vigorously reduce the fountain pump energy consumption, energy conservation with a very significant significance.

In recent years, the pump industry has designed and developed many energy efficient products, such as IHF, CQB, FSB, UHB and other models of pump products, to reduce the energy consumption of the pump played a positive role. But in all fields of the national economy, due to the irrational selection, many of the pumps in an unreasonable operating conditions, operating efficiency is low, a lot of energy wasted. Some pumps because of unreasonable selection, can not be used, or the use of maintenance costs, low economic efficiency. Thus, the rational choice of the same energy-saving pump is also important.

The so-called rational election pump, is to consider the pump unit and pump station investment and operating costs and other comprehensive technical and economic indicators, so that in line with economic, security, the principle of application. Specifically, the following aspects:

1, to meet the requirements of the use of flow and head, which requires the pump operation point (device performance curve and pump performance curve of the intersection) often remain in the high-performance range of operation, so that both power and damage to mechanical parts.

2, the choice of fountain pump is not only small size, light weight, low cost, but also has good characteristics and high efficiency.

3, the fountain pump has good anti-cavitation performance, so that both reduce the depth of excavation pump, fountain pump does not make cavitation, smooth operation, long life.

4, the selected fountain pump construction pump station, less investment, low operating costs.

Second, fountain pump selection steps

(1) Data:

1, the media properties: media name, specific gravity, viscosity, corrosion, toxicity and so on.

2, the medium contained in the particle diameter, content.

3, the required flow: general industrial pumps in the process can ignore the leakage in the pipeline system, but must consider the process of change in the impact of traffic. Agricultural pumps If the use of open channel water, but also must consider the leakage and evaporation.

4, pressure: suction tank pressure, drainage tank pressure, pipe system pressure drop (head loss).

5, the pipeline system data: diameter, length, pipe type and number of accessories, sink to the pressure tank geometric elevation.

In the design layout pipeline, should note the following:

A, reasonable choice of pipe diameter, pipe diameter, at the same flow rate, the flow velocity is small, the resistance loss is small, but the price is high, the pipe diameter is small, will lead to a sharp increase in resistance loss, the selected pump head increase, With the increase in power, costs and operating costs have increased. So should be considered from the technical and economic point of view.

B, the exhaust pipe and its joints should consider the maximum pressure can withstand.

C, pipe layout should be arranged as straight as possible to minimize the pipe fittings and to minimize the length of the pipe must be turned when the bending radius of the elbow pipe diameter should be 3 to 5 times the angle as much as 90 Lt; 0 & gt; C.

D, the pump must be installed on the discharge side of the valve (ball valve or globe valve, etc.) and check valve. The valve is used to adjust the operating point of the pump. The check valve prevents the pump from reversing when the liquid is backflow and prevents the pump from hitting the water hammer. (When the liquid backflow, it will have a huge reverse pressure, damage to the pump)

(2) determine the flow

A, if the production process has been given the minimum, normal, maximum flow, the maximum flow should be considered.

B, if the production process only gives the normal flow, should consider leaving a certain margin.

For ns> 100 high flow low unexpected pump, the flow margin to take 5%, for ns <50 of the small flow and pump, the flow margin to take 10%, 50 ≤ ns ≤ 100 pump, the flow margin Take 5%, poor quality and poor operating conditions of the pump, the flow margin should be taken 10%.

C, if the basic data only to the weight flow, should be converted into volumetric flow.