2017年1月21日星期六

How to Rationally Use Deep Well Submersible Pump

Deep Well Submersible Pump Reasonable use of methods: deep shaft pump shaft pump guide bearing is filled with water in the pump for lubrication. Before operation, the pump tube has not been filled with water, should be pre-lubricating rubber shaft min. Through the pre-hole on the water section, into the lubricating water, pre-lubrication 3 ~ 5min before start. Deep well pump operation, the water level in the deep wells should not be reduced to the pump inlet pipe near the pump that the water should not be too large, so as to avoid moving water level drop is too large, so that a sharp reduction in water, causing pump vibration, Resulting in damage to the motor and water pump.
In order to ensure the safe and reliable operation of the deep well pump unit, the temperature of the motor bearing and the height of the lubricating oil in the oil sump should be checked and monitored regularly. The voltage, current and water pump pressure, water flow and temperature of each part are recorded regularly. parameter.
Vertical deep well pump equipment used, such as the motor voltage, current and pump pressure, water and other abnormalities occur, or the motor running abnormal sound, etc., should immediately stop the use of vertical deep well pump device , And checked.

Deep well submersible pump installation need what tools

What tools are required to install the deep well submersible pump and how to install the outlet section?
Commonly used tools are to install the tower or tripod, winch and a number of special tools, including the chain clamp, pipe clamp, drive shaft bearing plate head and pipe clamps and so on.
Installation of the water section: Before installation, the packing gland, the packing ring and the retaining ring should be taken out, and then the water outlet section should be lifted to align the center line of the shaft hole with the drive shaft and maintain a steady, So that the drive shaft just out of the hole out of the shaft hole. Such as the water section lifting slightly skewed, both the installation of difficulties, but also may damage the drive shaft end of the thread, even when the shaft will cause serious bending deformation. Driving shaft after the use of bolts will pump pipe flange fastened to the water section, and then into the packing pressure ring and retaining ring.

2017年1月20日星期五

How to install deep well submersible pump

Deep well Submersible pump installation method
A: pump installation steps down the well
1 Shipping:
Be careful when loading and unloading to avoid damaging the unit or breaking the cable insulation.
2 To test the unit, proceed as follows:
A. Open the filter, with the crowbar should be flexible rotation coupling;
B. (10-15 minutes) whether the phenomenon of water leakage, if the leakage, please contact the agent or in a timely manner, please contact the agent or water leakage, Manufacturer, until after the installation of the filter. And then shake the table to measure the insulation resistance of the motor, the resistance should not be less than 50 megohm.
3 wiring test turn:
A. Connect the motor lead to the power cable (see the connection method for the submersible cable). After connecting, connect the connector to the water and check the resistance of the connector to the ground Insulation resistance) is not less than 500 megohms.
B. (The best is the detergent water) at the same time a little jog about the motor start button (time not more than 2 seconds), observe the pump turn, do a good mark continued.
4 units to go down
A. (In particular the first pump under the new wells), with a rope hanging not less than the length of the unit pipe (diameter equal to the maximum diameter of the unit) down to the depth of the pump should be no jamming phenomenon.
B. Enable the hoisting equipment to go down the well, use the insulated cable tie (strictly forbid wire) to tie the cable to the well pipe (pay attention to the cable moderate tension), the flange place the cable into the cable groove to prevent the cable from fraying. When going down the table with the constant watch cable insulation resistance to observe the changes (to prevent the shaft wall frayed cable). If it is found that the insulation value decreases rapidly (less than 0.5 megohms), the unit is brought up to check the cause. After the completion of downhole can be debugged.
5 Debugging: very important, please install the electrical debugging seriously
A. Start time; according to the motor power, master in 10-20 seconds, high-power motor starting time should be longer accordingly.
B. Overload and over current debugging: After the unit starts, adjust the current adjustment button of the thermal relay slowly to less than the actual operating current, rotate a few times every time (interval 2-5 minutes) until the thermal relay operating unit stops working, Reverse the rotation can be a little scale.
C. Phase sensitivity debugging: the unit starts again, one by one off the knife switch fuse, so that the unit is working in two state, observe the thermal relay within 5 seconds to cut off the control power supply.
D. Short-circuit protection: This function is usually achieved by the power supply system, air switch, generally do not make field tests (more dangerous). Requires power supply system must be equipped with air switch (Model preferred DW10 type, followed by DZ type)
After commissioning the control cabinet can start the normal unit test run.

How to use a deep well submersible pump

Deep well submersible pumps are flooding and oil immersion are two, are composed of two parts pump and motor. In order to ensure the normal operation of the pump, the following methods must be used.
    1. Before using the deep well submersible pump, use the megger to check the motor insulation resistance, the minimum value can not be less than 5MΩ. Inspection method is a megger connected to the terminal on the pump cable, the other terminal connected to the motor shell, shake Megohmmeter to observe the insulation resistance.
    2. Check the cable for cracks, abrasions and other phenomena, if any damage should be replaced in time to prevent leakage.
    3. Flooding motor should be open irrigation bolts, filled with clean water after tightening bolts, and then dive into the water. If the oil-immersed motor is found to be leaking, replace the sealing element before diving into the water.
    4. Pump submerged in water before the pump should be filled with water, idle 1 to 2 minutes, and start 2 times, check the idling and start is normal. If the reverse, the two-phase wiring can be replaced.
    5. Check whether the pipe cracks, connection is strong.
    6. Do not pull the cable when the pump is submerged or lifted to avoid damage to the cable or disconnection of the connector.
    7. The power supply voltage should be controlled within 5% of the rated voltage or less. If the voltage is too high or too low, it will damage the motor.
    8. Pump submerged in water should be vertical, not oblique.
    9. Pumps may not deliver more water or mud. Flooding motor should always clean the sand inside the motor cavity, the replacement of motor cavity water.
    10. The actual pump head should be 0.8 ~ 1.1 times the rated head. This can improve the pump efficiency, energy saving, to avoid overloading the motor operation, extend the service life.
    11. After the pump is used, it should be cleaned, rust-proof on the metal surface, and stored in a dry place. Flooding motor should also be put clean water within the motor.

Precautions for use of mine submersible pump

Precautions for use of mine submersible pump
1, the installation of leakage protection Leakage protection device, also known as security, its role from the "security device" the three words can be understood. Because the submersible pump in the water, easy to leakage caused by power loss or even lead to electric shock accident. If the leakage protection device is installed, the leakage protector will cut off the power supply of the submersible pump to avoid leakage of electricity and ensure the safety if the leakage value of the submersible pump exceeds the operating current value of the leakage protector (generally not more than 30mA).
2, the power supply voltage is abnormal MO start in rural areas due to low voltage power supply line is relatively long, the end of the line voltage is too low is common. When the phase voltage is below 198 volts, the line voltage is lower than 342 volts, submersible pump motor speed down, when less than 70% of the rated speed, start the centrifugal switch will be closed, resulting in long start-up winding power and even burn Windings and capacitors. Conversely, a high voltage causes the motor to overheat and burn out the winding. Therefore, the submersible pump in operation, the operator must always observe the power supply voltage value, if less than 10% of the rated voltage, higher than 10% of rated voltage above, the motor should stop running, find out the cause and troubleshooting. In this case,
3, to avoid frequent switching Do not frequently switch on the submersible pump, this is because the pump will stop when the return flow, if the immediate start, the motor load will start, resulting in starting current is too large and burn out the winding. Due to the large current at start-up, the frequent start-up also burns the submersible pump motor windings.
4, let the mine submersible pump long-term overload to avoid submersible pump long-term overload, do not draw large amounts of sediment water and observe whether the current value specified in the nameplate value, if the current is too large, should Shutdown check. In addition, the dehydration pump running time should not be too long, so as not to make the motor overheating and burned.
5, the direction of rotation of the motor to be correct to figure out the direction of rotation of the motor, there are many types of submersible pumps are forward and reverse when the water can be, but the reversal of small water, the current is large, the reversal of a long time Will damage the motor windings.
6, cable installation and submersible pump insulation resistance requirements When installing submersible pumps, the cable to overhead, the power cord should not be too long. Submersible pump into the water or put forward not to force the cable to avoid breaking the power cord. Do not sink submerged pump in the mud, otherwise it will lead to bad motor cooling and burn motor winding. Installation, the motor insulation resistance should not be less than 0.5 megohm. In this case,
7, Qinqin to see the problems found in time to repair the regular checks should always check the motor, if found under the cracks, rubber seal ring damage or failure, should be replaced or repaired, to avoid water infiltration submersible pump.

Movement Rule of Deep Well SubmersiblePump Valve

Deep well submersible pump valve's motion law in addition to the linear motion of the vertical direction, and is accompanied by two kinds of rotary motion. When the piston velocity is small, the valve ball level weeks rotate; When the piston velocity is larger, the valve ball around the week of vertical horizontal biography and the hole edge horn is along the seat seat hole center axis of revolution. The rotating angular velocity is associated with the rate of movement of the plunger, the plunger speed, the greater the valve ball rotation angular velocity. The greater the special movement form the main valve ball and valve seat structure particularity and the impact of the fluid. Deep well pump valve is a ball valve, when the fluid around it activities, behind will occur from the phenomenon of boundary layer, at the same time produce a lateral move. Because of the symmetry valve ball, the lateral exciting force move along the valve ball near the equator of the cycle, the valve ball is not always located in the seat hole axis line. But deviate from an interval and tight against the seat edge rotation, this is the phenomenon of revolution.
Not disorderly fluid activities and relative deviation caused by fluid of valve ball valve ball activity differences, according to the error of valve ball will produce certain scratched, the transverse force is not applied to its. But in the horizontal plane and there is a certain eccentricity, the valve ball in the horizontal plane and a rolling, this kind of phenomenon is called an autobiography.

Common faults and reasons of deep well submersible pump

(1) Poor seal. After a period of use, sealing parts of the motor manufactured by high wear-resisting materials will be aged and worn and water leakage will be happened due to poor seal.
(2) Cannot pump water. Due to the damage of bearing, deep well submersible pump cannot pump the water.
(3) Stuck pump. The phenomenon that the impeller of deep well submersible pump is blocked by debris and deep well submersible pump cannot rotate while can hear the noise is called stuck pump.
(4) Electric leakage. There is automatic trip phenomenon when leakage protector in voltage transformer room closes switch blade.
(5) Outlet pipe is damaged and leaked. If rotation of the ammeter is normal and normal sound of pump wheel of submersible pump in deep well can be heard, while deep well submersible pump pumps little water or cannot pump water, it is often caused by the damage of outlet pipe of deep well submersible pump.