2017年2月5日星期日

Precautions for Start - up of Deep Well Submersible Pump

Precautions for Start - up of Deep Well Submersible Pump

(1) When starting at full pressure, push the closing knife once. If the buck start, should be pushed to the "start", such as the motor speed and current close to the rated value (time 15-20s), quickly pull the handle to "run" position.

(2) start time can not be too long, so as not to burn the motor. Two start time to be separated by more than 5min, one to prevent motor overheating; two is to prevent water backflow, resulting in load overload burned motor.

(3) In the cold motor, continuous forced start not more than three times, close to the allowable temperature of the thermal state, not continuous start.

(4) When the starting torque is too large can not start, the compensator can increase the standard step-down (from 70% to 80%).

(5) In order to further check the combination of various parts of the pump, in the official start-up operation before the point of pushing start compensator handle (time 2 ~ 3s), wait until everything is correct after a moment, you can officially start the operation .

Precautions for Safety Inspection after Installation of Submersible Pump

Precautions for Safety Inspection after Installation of Submersible Pump
First, submersible pump electric control cabinet (station) safety protection devices and precautions
1. Safety protection device
1). Control cabinet (station) are high and low voltage isolation zone
2) control cabinet (station) are grounded devices, and a ground symbol
3) Control cabinet (station) into the outlet and junction box are "high-pressure danger" signs and text
2. Safety Precautions
1) The operator of the control cabinet (station) must be a trained electrical technician.
2) The operator must comply with the electrical safety procedures. In this case,
3) The control cabinet (station) must be reliably earthed
4) Troubleshooting A power failure must be performed.
4, submersible pump transformer safety and precautions
1) alpine region should be equipped with a snow cover transformer to prevent short-circuit caused by the transformer.
2) The transformer has a grounding device, the installation must be reliable grounding.
3) Operation of the on-load tap-changer The shift must be operated during a power failure.
4) observe the transformer, we must pay attention to safety, should be kept with the live parts of a certain distance, should not be observed in the high side, in order to avoid electric shock.
5) charged observation of oil surface temperature, should maintain a certain distance, from the exposed part of the thermometer observed temperature, shall not touch the thermometer.
6) The installation and operation of the transformer must be carried out by a trained electrician
5, diving cable safety precautions
1) Submersible pump unit work properly, the operator can not touch the cable, should keep a certain distance with the cable.
2) after measuring the insulation resistance, the response to discharge.

Deep Well Pump What are the speed control method

Deep Well Pump What are the speed control method
  Deep well submersible pump is mainly used in life, water treatment, emergency rescue of mining accidents, industrial production, cooling and other aspects of treatment, with the well with the use of submersible pumps increases, in their work prone to problems, how well Working with the submersible pump to adjust, the problem has been more and more people's attention, the next for everyone to do a detailed description:
1, the use of motor speed to change the pump device operating conditions:
With the new technology, new materials, new technology applications, not only the liberation of labor productivity, but also to ensure product quality is stable and reliable. China is a vast country, in many areas of production equipment needs are not the same situation, but in China's industrial areas, wells with submersible pumps are also increasing. China's wells with submersible pump technology is still in the mid-development, technology should be further improved.
2, speed operation:
Speed ​​regulation refers to the operation of deep well pumps driven by variable speed motors. With its outstanding performance in handling problems, more people pay more and more attention to the use of this product in real production. How to maximize the value of its use, manufacturers and customers need to do more work and research, as long as the right direction in the development of deep well pump tomorrow will be even better.
3, can be achieved through the gate valve throttle:
That is to change the opening degree of mine pump water, off small valve, pipe local resistance increases, the pipeline system characteristic curve steep, pump operating point will make corresponding changes, a corresponding reduction in water. When the gate valve is fully closed, the local resistance of the pipeline is close to infinity, the water is cut off. This will be more suitable for production.
   The deep well pump type has the QJ well to use the submersible pump and the QJT submersible pump, they are the deep well pumping water main force. QJ well submersible pump is a kind of high-quality submersible pump with heat-resisting, antisepsis, anti-aging and using temperature of 120 ℃. QJT submersible pump is a kind of submersible pump with compact structure, small volume, light weight, installation, use, Safe and reliable transportation, energy conservation and other advantages of the wells with submersible pumps.

How to determine the installation of submersible pump height

How to determine the installation of submersible pump height
First, the importance of pump installation height
  The normal work of the pump is based on the water pump to meet its water absorption conditions for the premise. In many cases, the pump device failure, can not work properly, often due to improper selection of water conditions caused. The correct water absorption conditions, refers to the pumping process, the pump does not produce cavitation case of the maximum water absorption height. Therefore, the analysis and study of pump cavitation and harm, to understand the water pump performance and influencing factors, to determine the pump installation height for the proper use of water pumps is very important.
Second, the pump how to determine the installation height
   Water pump at work, because the pump impeller is rotating at high speed, the pump impeller population in the formation of a negative pressure in the inlet water surface pressure and water pump impeller suction mouth of the absolute pressure difference under the effect of water from the inlet water pipe Flow into the impeller of the import. As a barometric pressure equal to 10.33mH2O high, so the maximum suction pump height does not exceed 10.33m. In fact, the pump running in the pipeline and the elbow will have head loss, which shows the installation height of the pump is far less than 10.33m. Under normal circumstances is to use the local atmospheric pressure - centrifugal pump NPSH -0.5m = pump installation height.

Advantages of deep well pump matching frequency converter

Advantages of deep well pump matching frequency converter
First, the frequency changer has the very strong protection function, the water pump overload, the overflow, the stall, the undervoltage, the over voltage and so on causes the water pump damage factor to protect in time, does not cause the water pump to burn.
Inverter to start when the soft start i pump, the pump speed from 0 to 0 in accordance with the acceleration time, slowly increase the speed, thus reducing the impact of large current pump start, but also reduces the start of the pump very quickly start the wear and tear .
When the pump stops, the inverter will stop the pump according to the deceleration time. This will reduce the water hammer caused by the sudden water stoppage and water retention in the pipe network, which will cause great damage to the pump.
Practice has proved that the use of variable frequency constant pressure control can make the life of the pump more than doubled, but also can effectively reduce the number of pump maintenance
Can save electricity, reduce water supply costs
Second, the frequency conversion control can make the deep well pump when the water consumption is small, reduces the water pump the rotational speed, thus consumes the electric energy also to reduce, the deep well pump is the square torque load, its power and the rotational speed third power is direct, For the rated speed of 60%, its power is rated 21.6%, can save 78% of the energy, In addition, the use of frequency control, can improve the power factor, the reactive energy into active power, practice, Frequency control rate of at least 30%
.
Third, the intelligent control Automatic operation:
Water supply equipment using PID closed-loop regulation, constant pressure, high precision, small hydraulic pressure fluctuations. With overload, short circuit, over-current and other automatic protection function, equipment operation is stable, reliable, easy to use and maintain. With the lack of water to stop the pump, automatic switching time pump running functions, can achieve unattended. Can establish a remote monitoring system, real-time monitoring equipment operation.

2017年2月4日星期六

Deep well water pumps commonly used in three start and control circuits

Submersible pumps commonly used in the three start and control circuits, Deep well water pump motor control and protection of common lines and start as follows.
(1) With the autotransformer step-down start control protection circuit (Figure 2-1) Start, close the power switch, turn on the power, press the start button, contactor 3KM power, its contacts will autotransformer When the time relay delay time, through the middle relay 2KB disconnect the contactor 3KM and 2KM, while making the contactor 1KM (1KM), the contactor 2KM and the time relay K energized, the motor starts to start, Power, the rated voltage to the normal operation of the motor, then start the signal light 2HL off, running lights 1HL light.
For oil-filled wells with submersible motors, when the oil pressure in the pressure-holding device is exhausted, the signal contact of the lean-oil protection is actuated and the oil-lean signal is issued, and the contactor is interrupted by the intermediate relay 1 KB. Oil-type motor stops working, at this time, lights 3HL light.
The use of autotransformer step-down start control protection circuit for any connection with the wells with submersible motors, use a wide range.
(2) start using a star-delta protection control circuit (Figure 2-2) start, close the power switch, turn on the power, lights HLG. Press the start button S. , The contactor KM energizes and makes the contactor K2 and the time relay K3 energize, the main contact of the contactor K2 connects the starter with the submarine motor stator winding, the electric motor starts the depressurization to start, starts the signal lamp HLY to be bright at the same time; When the time relay extends , The contactor K2 is disconnected and the contactor K1 is energized. At this time, the main contact of the contactor K2 is opened first, and then the main contact of the contactor K1 is closed to transfer the stator windings of the submersible motor into triangles Normal operation under the connection, lights HLY, HLG off, running lights HLR light.
When the submersible motor is overloaded, the control switch FR is closed and the control power is cut off by the intermediate relay K. The contactors KM and Ki are de-energized and the main power is turned off. The motor is stopped and the signal lamp HLR is off. The signal lights HLY, HLG light.
Star-delta control of the start of a protective control device easy to control, low cost, for delta connection, power larger, with double cable leads to the wells with submersible motor.
(3) wells with submersible motors commonly used control and protection devices for oil-filled wells with submersible motor, with the oil-poor signal action circuit commonly used control and protection devices are GKD type and XKD type, XKQ type. Applicable to water-filled or dry well submersible motor, and has a water level automatic control function of the common control and protection devices are JBXQ type.

Deep well water pump cooling

Deep well water pump cooling
Machine outside the water cooling, the machine air cooling
This cooling method is mainly used in deep well water pump and submersible sewage pumps. The inner cavity of the dry motor is filled with air, and the heat dissipation of the stator winding end and the rotor mainly depends on the air inside the machine. Stator iron loss of the stator, slot stator windings taken away by the casing surface water. The rotor winding resistance loss and rotor iron loss generated by heat, part of the air gap directly to the stator core, the shell passed to the motor outside the well water away; the other part of the machine to the air, this part Heat and stator end windings to another part of the air resistance loss heat and mechanical loss of heat generated by the machine flow of air to the stator core, housing and bearing seat, and finally through the motor housing and bearing seat And other parts of the surface to the motor outside the well water away. Because of the poor thermal conductivity of air, heat capacity and very small, so wells for type submersible motor stator windings and rotor windings of the cooling conditions are poor, the temperature rise is relatively high. In this case,
Machine water cooling, machine oil cooling
The stator iron loss, the stator slot winding resistance loss and the partial winding loss resistance heat generated directly through the stator core, through the casing to flow through the casing surface of the well water away. Rotor rotor resistance loss and iron loss of the heat generated by the part of the oil in the air gap directly to the stator, the shell passed to the motor outside the well water away; the other part of the transfer to the rotor cavity filled In this case, the heat is transferred to the stator core, the housing and the bearing via the oil filled in the cavity together with the heat generated by the loss of heat from the other part of the stator fluid passed through the stator end winding and the mechanical loss. Seat, and finally through the motor housing and bearing parts and other parts of the surface to the well water away from the motor. Oil-filled deep-well pump that is used in this cooling. Oil-filled motors are filled with insulating oil. The stator core, stator windings, rotor core and rotor windings (rotor bar and rotor end ring) are immersed in oil.
Outside the double water-cooled way, the electric motor inside
This motor inside and outside the cooling effect of dual water cooling, so well water-filled submersible pumps and wells with submersible pump stator windings are generally relatively low temperature rise. The stator core, stator windings, rotor core and rotor windings (rotor bar and rotor end ring) are immersed in the water, directly from the machine's internal water pump, Water cooling. The stator iron loss, the stator slot winding resistance loss and the partial winding loss resistance heat generated directly through the stator core, through the casing to flow through the casing surface of the well water away. The rotor winding resistance loss and rotor iron loss generated by heat, part of the air gap directly to the stator, the stator to the motor outside the well water away; the other part of the rotor cavity to the water, this part of the heat and the stator end The internal windings pass to the cavity filled with water, another part of the loss of heat and mechanical loss of heat generated by the cavity filled with water to the stator core, housing and bearing, and finally through the motor housing and bearing blocks and other zero The surface of the part is carried away by the well water. In this case,
The rotor is directly cooled by water, and the stator case is cooled by water
Motor stator iron loss and stator winding resistance loss of heat generated directly through the stator core or cavity filling, the shell passed through the casing surface of the well water away. The rotor winding resistance loss and rotor iron loss generated by heat, part of the air gap through the water and shield directly to the stator, the stator to the motor outside the well water away: the other part of the rotor cavity to the charge Of the water, this part of the heat and mechanical loss of heat generated by the cavity filled with water to the stator core, housing and bearing seat, and finally through the motor housing and bearing parts and other parts of the surface specifically to the motor outside Of the well water away. This cooling method is mainly used for wells with shielded submersible motor. The motor stator is a separate sealed chamber, the stator core and winding encapsulation, filled with epoxy resin or plastic filler, the rotor cavity filled with water.