2016年12月5日星期一

Advantages of vertical mixed flow pump

1. Operation simple horizontal pump, because the impeller is above the water, before the pump starts, to use a vacuum pump to pump water, because the vertical pump impeller, generally submerged in water, can be directly launched.  
2. Installation area contains the driver, including the vertical pump, only half of the space on the pump to meet the. Especially in the large pump today, this advantage is more outstanding.  
3. Is conducive to prevent cavitation vertical pump impeller generally submerged in water, you can use the NPSH can take a large number of. Thus, the pump running at a greater than the planning point of the flow will not attack cavitation.  
But because it is a vertical, longitudinal longer pump, disassembling and assembling crane hoisting height is higher, above the pump to have space to meet, this is the disadvantage of the vertical pump. However, the vertical mixed flow pump is simply installed outdoors, so it will not become a question.  

How to start and run the high temperature liquid pump

Starting, stopping and running requirements of the  high temperature pump :

1.  The liquid pump motor is not installed, the power should be turned on to check the direction of rotation must be consistent with the provisions of the pump rotation direction.  
2. Liquid pump installed on the motor, the disc dynamic coupling, check the pump shaft and motor is concentric, whether the weight of the rotation is not uniform, and then run the normal.  
3. Liquid pump off the outlet pipeline valve and pressure gauge.  
4. The liquid pump starting motor, the pressure gauge to open the outlet valve to the required position.  
5.  The liquid pump normal parking, you should first close the outlet valve, and then stop the motor, close the pressure gauge.  
6.  Liquid pump bearing chamber should ensure enough oil, bearing temperature rise shall not be higher than 70 .

Selection method of deep well pump

1.  According to the dynamic situation. The local well pump supply chains vertical well tube, primary pump. Generally speaking, if the local power supply is guaranteed, the best selection of Submersible pump, because of its light weight, simple to install and use, the verticality of the well pipe requirements is relatively low. Opposite, if the areas without electricity, or power supply to assurance, and verticality of well pipe and relatively good, select diesel engine driven deep well pump.  
2.  According to the well diameter preliminary determination of the model of the deep well pump. The minimum borehole diameter and the diameter of pump used must conform to, as well as 8 inches diameter, deep well pump should be less than 8JD. But in general, in order to ensure the installation is convenient, the well diameter shall be 2 inches larger than the minimum well diameter of the well pump.  
3.  According to the maximum water quantity of well selected pump type. The maximum water inflow well in general should be based on the well pumping test to determine. But because of equipment limitations and can not be pumping test, estimated on the basis of well washing water inflow and water level drawdown data.  

Structural principles and advantages of deep well pump

Two kinds of pumps are made of three parts. One is well on the part, which comprises a motor, a bearing box and a pump seat, used for supporting power, weight, nitric pump water diversion. Two is in the same transmission part, including the water delivery pipe, transmission shaft and bearing bracket, etc., from the transmission power and compliance. Three is the underground part, including the leaf Han, pump shell, Ye Hanzhou, etc., is the body of the pump, the water absorption, water extraction.  
The working principle of the well pump is basically the same as that of the general horizontal centrifugal pump. The power is driven by the driving shaft to drive the pump impeller to rotate, the vacuum is formed at the inlet of the impeller, and the well water is sucked. In order to reduce the energy loss of the water conveyance, the high speed water flow from the blade is eliminated by the flow guiding shell, and then flows along the water pipe to the farmland through the water head.  

Deep Well pump has the following advantages:  

1. The  straw has the advantages of simple structure, the material and process requirements is not high, easy to manufacture.  
2. high efficiency.  
3. The engine installed in the wells, convenient installation.  
4. Leaves immersed in water, do not need to water before starting.  
5. The price is cheap.

Improper selection of fountain pump and operation error

The following experts gave some of the fountain pump to solve the corresponding problems of the proposed solution:
1. Two pumps in parallel shall ensure that the pump performance is the same. Pump performance curve should be slow down for good, can not have a hump.
2. Ushould pay attention to: lead to the elimination of fountain pump overload factors, such as clogging; appropriate to extend the pump opening time, reduce the disturbance of the drive shaft, rotary impact and friction between parts and stationary parts is decreased, and the resulting thermal deformation; for water lubricated sliding bearing, start process should be full of pre moistened water skiing, avoid dry start, until the water pump to stop pouring.
3. Regular to the needs of the amount of oil bearing oiling, for axis liquid centrifugal pump, because the shaft have a torsional vibration, if used with thrust, damage is mainly thrust, then can be an appropriate increase in the lubricating oil viscosity, prevent liquid dynamic pressure lubricating film damage.
4. The fountain pump is recommended in order to prevent the fountain pump is too large, you can also use the measurement and analysis of vibration conditions to determine the best working parameters of the pump

Installation and installation work order of submersible axial flow pump

Preparation before installation :

1. Measuring and checking the installation position of the axial flow pump in the construction site and measuring the discharge line to determine the installation coordinate of axial flow pump and shaft axis reference line. 
2.  Inspection and acceptance, the quality inspection of the appearance of the axial flow pump and the shaft parts, and random data should be complete. 
 
3. Artificial crane, truck after unpacking inspection of axial flow pump, shaft parts and transport to the construction site. 

Installation and installation work order of submersible axial flow pump

Shaft installation: 

1.According to the equipment on the line of the reference point, the first installation of the fixed bearing. 
 
2.With the manual lifting machine will be in place, if the shaft is longer, in the lifting process should avoid collision with other objects in the wellbore and cause damage to the shaft. 
 
3.Shaft lifting, the shaft is fixed, the righting leveling, ensure the wellbore verticality is less than 1/1000, length of not more than 3mm (with wire and straightedge check). 

Axial flow pump installation:

1.The shaft installation is fixed, and after the adjustment of the adjustment of the allowable deviation value, the axial flow pump installation work. 
 
2.With the manual lifting machine to lift the axial flow pump to the shaft mouth, and then the axial flow pump down the shaft slowly down to the bottom of the shaft bearing, the axial flow pump to the leveling, and then tighten the fixed bolt. 
 
3.Deviation and test method for installation of axial flow pump.