2016年11月4日星期五

Submersible pump manufacturers to talk about the pump lift and what is relevant

Many users to buy pumps, we may know that the pump is the head of what is the decision, and today we are talking about the Shanghai Submersible Pump manufacturers, I hope the person is not very understanding of the pump help.
     First of all, we talk about what is the pump head, the pump is the lift pump can lift the height. Then talk about the pump head and what a relationship.
     The first is the relationship with the blade exit angle, when the other for the fixed value, the larger the blade exit angle, with the flow of the theoretical lift also increased accordingly.
     Second, with the number of leaves, as the corresponding, the other for the fixed time, regardless of the case of flow loss, the more the number of leaves, the greater the theoretical lift.
     Third, there is a relationship with the speed, here involves an equation, the Euler equation can be drawn, the higher the speed, the greater the lift.

2016年11月3日星期四

Submersible pump should be how to selection

When we choose the submersible pump, we should first consider whether the normal submersible pump manufacturers, and then confirm the parameters, understand the market conditions, to confirm the price of submersible pumps, the following we say for the submersible pump selection method.
1, the submersible pump flow is selected one of the important performance data of submersible pumps, it is directly related to the entire production capacity and transmission capacity. Such as the Design Institute process design can calculate the pump normal, minimum, maximum three kinds of traffic. Select the submersible pump, based on the maximum flow, taking into account the normal flow, in the absence of maximum flow, it is usually desirable to 1.1 times the normal flow as the maximum flow.
2, the installation system is required to lift the pump is another important performance data, the general use of amplification 5% -10% margin to head selection.
3, the liquid properties, including the name of the liquid medium, physical properties, chemical properties and other properties, the physical properties of the temperature c density d, viscosity u, solid particles in the media diameter and gas content, which involves the system head, Erosion margin calculation and the appropriate type of pump: chemical properties, mainly refers to the liquid medium of chemical corrosion and toxicity, is the choice of pump material and the choice of an important basis for the type of shaft seal.
4, the device system piping layout conditions refer to the high degree of liquid to send liquid to send liquid from the direction of the suction side of the minimum liquid level, the discharge side of the maximum liquid level and some data and pipe size and length, material, pipe specifications, the number And so on, in order to carry out the comb head calculation and the NPSH check.
5, the operating conditions are many, such as liquid operation T saturated steam power P, suction side pressure PS (absolute), discharge side container pressure PZ, altitude, ambient temperature operation is the gap or continuous, the location of the submersible pump Fixed or movable. Submersible pump with high speed, small size, light weight, high efficiency, large flow, simple structure, no pulsation of the infusion, stable performance, easy operation and easy maintenance and so on. So that the selected submersible pump type and performance in line with the device flow, head, pressure, temperature, cavitation flow and other process parameters. Mechanical reliability, low noise, vibration. The economy to take into account the equipment costs, operating costs, maintenance and management costs the lowest total cost.
 
Therefore, in addition to the following circumstances, should be used as far as possible submersible pumps:
1, metering requirements, the choice of metering pumps
2, the head request is very high, the flow is very small and not suitable for small flow high-lift submersible pump can be used, the choice of reciprocating pump, such as cavitation requirements are not high can also use the vortex pump.
3, head is very low, large flow, the choice of axial flow pump and mixed flow pump.
4, medium viscosity (greater than 650 ~ 1000mm2 / s), consider the choice of rotor pump or reciprocating pump (gear pump, single screw pump)
5, the medium containing 75% of the gas flow rate is small and the viscosity is less than 37.4mm2 / s, the choice of vortex pump.
6, the start of frequent or inconvenience irrigation pump occasions, should be used with self-priming performance of the pump, such as self-priming pump, self-priming vortex pump, pneumatic diaphragm pump.

Submersible pump unit installation steps

When we use the submersible pump, the use of the submersible pump the entire unit, submersible pump unit installation is how to install it? The following by the Shanghai Submersible Pump manufacturers and we say, we want to help:
First, the pump outlet to install a pump tube, and clamped with a clamp, hanging down into the well, so that the splint is located in the well stage.
Second, a pair of plywood and then clamped another section of water pipes. Then lift, lower and then connected to the flange of the flange connected with the pad, the screw must be diagonal at the same time. Raise the lifting chain to remove the first clamping plate, so that the pump down the splint and fell on the well stage. Repeat installation, go down, until all Zhuangwan, put the covers, the last pair of splints will not be demolished on the covers.
Third, the installation of elbow, gate valve, outlet, etc., and add the appropriate pad seal.
Fourth, the cable to be fixed in the groove on the water pipe flange, no section with a rope fixed, down the process to be careful not to bruise the cable.
Fifth, the process of the next pump, if the card is not the main phenomenon, then we must find ways to overcome the card point, can not force the next pump, in order to prevent being stuck.
Sixth, the installation is strictly prohibited personnel down the job.
Seventh, the protective switch and starting equipment should be installed in the user’s distribution board, the distribution board has a voltmeter, ammeter, light, and placed in the well room in place.
Eighth, the use of “wire from the motor base to the pump tube bundled,” the force of protection measures, in order to prevent accidents from happening.

what are the reasons of Stainless steel submersible pump motor overload

Stainless steel submersible pump material can be divided into 304,316 and 316L and so on, whether it is stainless steel or cast iron, the motor overload and the material does not matter, then lead to submersible pump motor overload what are the reasons? Here are the manufacturers of Shanghai submersible pump and we say.
First, the supply voltage is too low
Submersible pumps in rural areas under the conditions of more than rated voltage operation, the stator windings in the current increase more, resulting in stator winding temperature rise more and more overheating burned.
Second, pump selection improper
The actual use of the load conditions and the selected submersible pump does not match the form; selected submersible pump head is too high or too low.
Third, mechanical failure
Stainless steel submersible pump bearings are seriously damaged, stator and rotor friction “swept chamber” or pump impeller and other debris by water and other debris and other mechanical failure will result in submersible sewage pump stator winding burned.
Fourth, the quality factor in the manufacturer or repair
Stainless steel submersible pump manufacturers and repair quality causes submersible pump overload.

Causes of Common Problems in Deep Well Submersible Pumps

When we use the submersible pump, it may encounter some problems, so how should we operate? What are the causes of the problem? The following by our Shanghai Submersible Pump factory and we say, to give you a reference.
The first may encounter problems with nerve submersible pumps starting or running with large currents and sometimes even tripping
The reasons for this are:
1, power failure, power shortage.
2, the power cord is too long too small, the pressure drop is too large or the supply voltage is too low.
3, contactor damage or thermal relay trip. (Fault red light)
4, the power cord into the motor line, automatic box within a break or loose into the line phase.
5, the motor has been damaged.
6, the pump has a foreign body card machine.
Let me talk about the exclusion method:
1, check the power supply, excluding phase.
2, increase the cable, improve the supply voltage.
3, check or replace the contactor, thermal relay to be manually reset after cooling.
4, check the line is good.
5, check the motor or replacement.
6, clean up foreign body.
The second problem is the deep well submersible pump pumping is not the water or the water current is too large or too small
cause:
1, pump reversal.
2, the pump head is too high, the actual head low.
3, pumped into the water is blocked.
4, the motor windings on the thermal insulation resistance of less than 0.5 megohm.
5, the aging of electromagnetic wire insulation or damage.
6, rubber cable damage.
7, sealing joint failure.
Solution:
1, open the winding, with self-adhesive tape bandage or re-wound around the new coil.
2, to find the damaged place, with self-adhesive tape re-bandaged.
3, split, good, re-bandaged.
The third problem is the deep well submersible pump no water or intermittent effluent or water less failure
cause:
1, the motor does not start (such as voltage, wire too small too long, the cable pressure drop too large or stuck pump start is not up)
2, pipe plugging or drainage network blocked.
3, pipe rupture or gasket damage.
4, suction surface exposed.
5, submersible pump steering the opposite.
6, Impeller ring and seal ring wear.
Let me talk about the exclusion method:
1, remove the circuit fault, find out the cause of stuck and ruled out.
2, clear the blockage.
3, repair rupture Department.
4, decentralization submersible pump, if still no water, may be more than submersible pump lift range, the proposed change pump.
5, the exchange of any two cable connector.
6, replace the new impeller, seal ring.

How to improve the life of the stainless steel pump

First, confirm the correct direction of motor rotation
Should find out the direction of rotation of the motor, there are many types of submersible pumps are forward and reverse when the water can be, but the reversal of the small amount of water, current, if the reversal of a long time will damage the motor winding.
Second, prohibit the power supply voltage abnormal boot
As the low-voltage power supply line is relatively long, the end of the line voltage is too low is common. When the phase voltage is below 198 volts, the line voltage is lower than 342 volts, submersible pump motor speed down, when less than 70% of the rated speed, start the centrifugal switch will be closed, resulting in long start-up winding power and even burn Windings and capacitors. Conversely, a high voltage causes the motor to overheat and burn out the winding. Therefore, the submersible pump in operation, the operator must always observe the power supply voltage value, if less than 10% of the rated voltage, higher than 10% of rated voltage above, the motor should stop running, find out the cause and troubleshooting.
Third, the cable installation and submersible pump insulation resistance requirements
Install the submersible pump, the cable to overhead, the power cord should not be too long. Submersible pump into the water or put forward not to force the cable to avoid breaking the power cord. Do not sink submerged pump in the mud, otherwise it will lead to bad motor cooling and burn motor winding. Installation, the motor insulation resistance should not be less than 0.5 megohm.
Fourth, the installation of leakage protection
Leakage protection device, also known as protectors, its role from the “security device” the three words can be understood. Because the submersible pump in the water, easy to leakage caused by power loss or even lead to electric shock accident. If the leakage protector is installed, the leakage protector will cut off the power of the submersible pump to ensure the safety and avoid the leakage and waste of the electric energy as long as the leakage value of the submersible pump exceeds the operating current value of the leakage protector (generally not more than 30mA).
5, to avoid frequent switching
Do not frequently switch the submersible pump, this is because the pump will stop when the return flow, if immediately start, the motor load will start, resulting in too large starting current and burn the winding. Due to the large current at start-up, the frequent start-up also burns the submersible pump motor windings.
6, let the submersible pump long-term overload
In order to avoid long-term overload of submersible pump work, do not smoke a large amount of water and observe the current value is on the nameplate value, if the current is too large, should stop checking. In addition, the dehydration pump running time should not be too long, so as not to make the motor overheating and burned.
7, pay attention to routine maintenance
Usually should always check the motor, if found under the cover of a crack, rubber seal ring damage or failure, should be replaced or repaired in time to avoid water infiltration submersible pump.

Submersible pump should be how specific maintenance

Submersible pump is a major water pumping device, then how should the repair and maintenance of it? The following by the Shanghai Submersible Pump manufacturers and we talk about, but also to provide a reference.
Before using the maintenance
1, submersible pump if not used for a long time and on the water when used before the pump from the machine downhole or other waters put up to check the parts, rust paint, to prevent corrosion of parts.
2, running 2-3 years of submersible pumps, pumps and motors should be removed, cleaning all the parts, but also remove the screws, cleaning the impeller in the chamber of sediment and debris.
3, check the pump and motor bearings, impeller ring, thrust bearings, thrust plate and other vulnerable parts, wear serious to be replaced.
4, check the pump on the fasteners, rust slowly unscrew, ritual a little oil , damaged to be replaced.
5, check the sealing parts of the pump, and some because of friction and washer rot, water into the sealed cavity, so that the rotating parts rust and not flexible or simply turn fixed. For the corrosion of the moving parts and damaged seals, to re-replace the new pieces.
6, to check the cleaning and repair parts, re-assembly together. Assembly, the bonding surface and the fastening body should be coated with butter, to prevent rust, affecting the next demolition.
If after a few steps above the maintenance, submersible pumps can basically be used normally.
If there is need to store, then the storage should be how to maintain it? Here we continue to say.
1, when not in use, the pump should be stored in the ventilation drying room, so as not to damp motor.
2, wet submersible pump storage in winter before storage, you must let go of the internal lubrication of the motor cooling water, so as not to freeze frozen bad motor.