Responding to the necessary maintenance of the agricultural submersible pump to extend its service life and ensure the normal use of busy:
1, the replacement of lubricants: respectively, open the sealed chamber and the motor inside the oil hole screw, the sealed indoor and motor internal lubricants all release, replace the new oil to ensure that the lubrication system to work properly.
2, check the wearing parts: submersible pump impeller, buckle, sleeve, bearing, etc. are wearing parts. First part of the pump should be removed, check the wearing parts are intact. Do not use damaged and unqualified spare parts.
3, the demolition of the pump shell rust: spring before use, should be opened the last level of the pump shell, turn the wheel after the closing start to prevent the parts rust can not start normal and burn the motor. This maintenance is particularly important for water-filled motors.
4, dry motor: 500 megohm meter measuring submersible pump winding and shell insulation resistance, if the resistance is less than 0.5 megohm, you should get rid of motor moisture. Drying methods are: external drying method, current drying method and the simultaneous co-drying method. External drying method is the use of external heat source for processing, commonly used measures are: ⑴ blowing hot air: the use of electric heater blower (agricultural small submersible pump available hair dryer) blowing hot air to achieve the purpose of drying; ⑵ bulb baking: Sealed box, the use of a number of about 200 watts of bulbs for baking. Note that the baking temperature can not be too high, should be controlled below 125 ℃; ⑶ current drying: According to the submersible pump impedance and power supply size of the motor three-phase winding in series or parallel, and then access a variable resistor, adjust the current For the rated current value of about 60%, power drying.
5, to ensure that the seal: agricultural submersible pump on the sealing requirements are very strict, in the replacement of sealed indoor lubricating oil, if found oil turbidity and high water content, you must replace the whole or replace the sealed box or seal ring to ensure its seal Good performance.
6, check the bearing: check the motor part of the upper and lower bearings, if found to wear or clearance is too large, to be timely replacement of new bearings, is strictly prohibited "sick" improvise. Check the method is as follows: If the motor is running, resulting in "carbazole" sound, and the cycle is proportional to the speed, and hand when the rotor is laborious, bearing raceway is a bit astringent or avulsion phenomenon; if the bearing intermittent Of the "choking choked" sound, hand rotation of the rotor when there is uncertainty of the dead point, the ball is generally damaged, broken inner ring or broken ball. Encountered the above situation, you must replace the bearings, so as to avoid greater damage.
7, to ensure that bearing lubrication: the water-filled submersible pump should be checked to replace the upper and lower end of the bearing chamber skeleton oil seal and lithium grease. To ensure that the bearing long-term work in a good state of lubrication.
2017年4月1日星期六
2017年3月16日星期四
What are the advantages of vertical mixed flow pump?
Mixed flow pump, commonly used in farmland irrigation and drainage, industrial and urban water supply and drainage and other occasions. According to the different types, mixed flow pump is divided into horizontal mixed flow pump and vertical mixed flow pump. Although both are mixed flow pumps, but both have obvious differences and differences. So, for the horizontal mixed flow pump, vertical mixed flow pump which advantages and advantages?
From the author years of experience in the pump, vertical mixed flow pump has the following major advantages:
1, simple operation
Horizontal mixed flow pump, because the impeller is above the water, before the pump starts, use a vacuum pump to the pump water. While the vertical mixed-flow pump, because its impeller usually sink in the water, can be started directly.
2, the installation area is small
Compared to the horizontal mixed flow pump, vertical mixed flow pump installation area only need horizontal mixed flow pump is generally enough. Greatly saves the floor space.
3, more anti-cavitation
Vertical impeller pump impeller is usually sinking in the water, can take advantage of the NPSH can take a larger number. For this reason, cavitation is less likely to occur.
From the author years of experience in the pump, vertical mixed flow pump has the following major advantages:
1, simple operation
Horizontal mixed flow pump, because the impeller is above the water, before the pump starts, use a vacuum pump to the pump water. While the vertical mixed-flow pump, because its impeller usually sink in the water, can be started directly.
2, the installation area is small
Compared to the horizontal mixed flow pump, vertical mixed flow pump installation area only need horizontal mixed flow pump is generally enough. Greatly saves the floor space.
3, more anti-cavitation
Vertical impeller pump impeller is usually sinking in the water, can take advantage of the NPSH can take a larger number. For this reason, cavitation is less likely to occur.
Deep well pump selection method and principle
Deep well pump selection method and principle
Deep well pump can be called deep water pump, well pump, well submersible pump, he is a kind of submersible pump, but deep well pump pump inside the number of impellers a lot, so we call it multi-stage submersible pump.
Deep well pump before pumping the pump, the first step is to work with water. There is a water hole above the motor, must be filled with water to cool the motor, then install the outlet pipe and then connect the cable, the deep well pump into the liquid completely submerged, open pump, the impeller high-speed rotation, the liquid with the leaves Rotate together, in the role of centrifugal force, flying out of the impeller outward, the liquid injection in the pump chamber diffusion speed gradually slow down, the pressure gradually increased, and then from the pump outlet, the discharge pipe out. At this point, at the center of the blade at the center of the liquid is thrown to the surrounding and the formation of both no air and no liquid vacuum low pressure area, liquid pool in the pool of atmospheric pressure under the action of the suction pipe into the pump, the liquid is so continuous Constantly being sucked up from the liquid pool and continuously flowing out of the discharge pipe.
Submersible pump basic parameters
Including flow, head, pump speed, matching power, rated current, efficiency, outlet diameter and so on.
Submersible pump composition
By the control cabinet, diving cable, Yang water pipe, submersible pump and submersible motor.
Submarine pump main purpose and scope of application
Including mine rescue, construction and construction of drainage, water and agricultural irrigation and drainage, industrial water cycle, urban and rural residents cited water supply, and even disaster relief and so on.
Deep well pump has the characteristics of high flow and high head. Let's take a look at the deep well pump
1. Deep well pump should be used in the sand content of less than 0.01% of the water source, the pump room equipped with pre-water tank, the capacity should meet the start of a pre-run water. The following are the same as the "
2. New or overhauled deep well pump, should adjust the pump shell and the impeller clearance, the impeller in the operation shall not friction with the shell.
3. Deep well pump should be running before the water into the shaft and bearing the shell for pre-run.
4. Before the start of the deep well pump, the inspection items should meet the following requirements:
1) base base bolts are tightened;
2) axial clearance to meet the requirements, adjust the bolt nuts have been installed;
3) the packing gland is tightened and lubricated;
4) motor bearings have been lubricated;
5) Rotate the motor rotor and stop mechanism by hand are flexible and effective.
5. Deep well pump can not be idle in the case of water. Pumps One or two impellers should be immersed below water level 1m. Operation should always observe the changes in the water level in the well.
6. During operation, when you find a large vibration around the foundation, you should check the pump bearing or motor filler wear; when excessive wear and leakage, should replace the new pieces.
7. has been sucked, drained with mud deep well pump, before stopping the pump, the application of water rinse.
8. Before stopping the pump, you should close the water valve, cut off the power, lock the switch box. When the winter is disabled, the water should be placed in the pump.
The above describes the basic principles of deep well pump and precautions, we have to figure out the parameters of deep well water pump to confirm after the selection. Deep well pump selection method is not so complicated, according to the actual requirements to choose deep well pump to do foolproof.
Deep well pump can be called deep water pump, well pump, well submersible pump, he is a kind of submersible pump, but deep well pump pump inside the number of impellers a lot, so we call it multi-stage submersible pump.
Deep well pump before pumping the pump, the first step is to work with water. There is a water hole above the motor, must be filled with water to cool the motor, then install the outlet pipe and then connect the cable, the deep well pump into the liquid completely submerged, open pump, the impeller high-speed rotation, the liquid with the leaves Rotate together, in the role of centrifugal force, flying out of the impeller outward, the liquid injection in the pump chamber diffusion speed gradually slow down, the pressure gradually increased, and then from the pump outlet, the discharge pipe out. At this point, at the center of the blade at the center of the liquid is thrown to the surrounding and the formation of both no air and no liquid vacuum low pressure area, liquid pool in the pool of atmospheric pressure under the action of the suction pipe into the pump, the liquid is so continuous Constantly being sucked up from the liquid pool and continuously flowing out of the discharge pipe.
Submersible pump basic parameters
Including flow, head, pump speed, matching power, rated current, efficiency, outlet diameter and so on.
Submersible pump composition
By the control cabinet, diving cable, Yang water pipe, submersible pump and submersible motor.
Submarine pump main purpose and scope of application
Including mine rescue, construction and construction of drainage, water and agricultural irrigation and drainage, industrial water cycle, urban and rural residents cited water supply, and even disaster relief and so on.
Deep well pump has the characteristics of high flow and high head. Let's take a look at the deep well pump
1. Deep well pump should be used in the sand content of less than 0.01% of the water source, the pump room equipped with pre-water tank, the capacity should meet the start of a pre-run water. The following are the same as the "
2. New or overhauled deep well pump, should adjust the pump shell and the impeller clearance, the impeller in the operation shall not friction with the shell.
3. Deep well pump should be running before the water into the shaft and bearing the shell for pre-run.
4. Before the start of the deep well pump, the inspection items should meet the following requirements:
1) base base bolts are tightened;
2) axial clearance to meet the requirements, adjust the bolt nuts have been installed;
3) the packing gland is tightened and lubricated;
4) motor bearings have been lubricated;
5) Rotate the motor rotor and stop mechanism by hand are flexible and effective.
5. Deep well pump can not be idle in the case of water. Pumps One or two impellers should be immersed below water level 1m. Operation should always observe the changes in the water level in the well.
6. During operation, when you find a large vibration around the foundation, you should check the pump bearing or motor filler wear; when excessive wear and leakage, should replace the new pieces.
7. has been sucked, drained with mud deep well pump, before stopping the pump, the application of water rinse.
8. Before stopping the pump, you should close the water valve, cut off the power, lock the switch box. When the winter is disabled, the water should be placed in the pump.
The above describes the basic principles of deep well pump and precautions, we have to figure out the parameters of deep well water pump to confirm after the selection. Deep well pump selection method is not so complicated, according to the actual requirements to choose deep well pump to do foolproof.
2017年3月14日星期二
Submersible Fountain pump working principle
QS submersible fountain pump is a fountain dedicated pump, the pump motor material using high-quality cold-rolled Xianguang, increase the number of motor windings and diving line diameter, cable with three-phase four-wire JHS fountain dedicated cable, impeller increased The anti-loosening device, the motor cavity using imported anti-rust enamel, through the above structure to improve the submersible pump inertia is small, so the response speed, bearing the use of high-performance dedicated shaft, improve the insulation level, so as to meet the frequent needs of the music fountain frequent start.
What is the working principle of the fountain pump? The following legislation will be the new irrigation and drainage equipment will introduce the working principle of the fountain pump.
Before opening the fountain pump, the suction pipe and the pump must be filled with liquid. After the pump is pumped, the impeller rotates at high speed, and the liquid rotates with the blade. Under the action of centrifugal force, it leaves the impeller outward and the liquid is gradually slowed down in the pump chamber, and the pressure gradually increases, Pump outlet, discharge pipe out.
At this point, at the center of the blade at the center of the liquid is thrown to the surrounding and the formation of both no air and no liquid vacuum low pressure area, liquid pool in the pool of atmospheric pressure under the action of the suction pipe into the pump, the liquid is so continuous Constantly being sucked up from the liquid pool and continuously flowing out of the discharge pipe.
What is the working principle of the fountain pump? The following legislation will be the new irrigation and drainage equipment will introduce the working principle of the fountain pump.
Before opening the fountain pump, the suction pipe and the pump must be filled with liquid. After the pump is pumped, the impeller rotates at high speed, and the liquid rotates with the blade. Under the action of centrifugal force, it leaves the impeller outward and the liquid is gradually slowed down in the pump chamber, and the pressure gradually increases, Pump outlet, discharge pipe out.
At this point, at the center of the blade at the center of the liquid is thrown to the surrounding and the formation of both no air and no liquid vacuum low pressure area, liquid pool in the pool of atmospheric pressure under the action of the suction pipe into the pump, the liquid is so continuous Constantly being sucked up from the liquid pool and continuously flowing out of the discharge pipe.
Characteristics and Application of Submersible Fountain Pump
Submersible Fountain pump its shell, over flow parts and external parts are made of cast iron or stainless steel (304,316,316 L) made, and the product also retains the original fountain dedicated pump performance.
Fountain dedicated pump features:
1, the use of cast iron or stainless steel, pump to improve the corrosion resistance.
2, impeller with special materials to prevent the impeller when the impeller loose.
3, leakage protection measures: the use of fixed potential grounding device.
4, on the basis of the original ordinary pump, according to the requirements of the fountain dedicated pump, the company after several tests, in the technical development, continuous improvement of processing materials, fountain dedicated pump can be frequent start, completely suitable for the use of music fountain.
5, the pump with stainless steel filter cover, three-phase four-wire cable.
6, stainless steel fountain pump for automatic water injection function.
7, the motor is self-circulating water-cooled.
Fountain submersible pump is mainly used for fountain water supply, aquaculture and other places. Widely used in low-lift cities, farmland irrigation and drainage, sprinkler irrigation, industrial and civil supply and drainage systems, hills, mountain water diversion, and low-lying areas to remove water.
Fountain dedicated pump features:
1, the use of cast iron or stainless steel, pump to improve the corrosion resistance.
2, impeller with special materials to prevent the impeller when the impeller loose.
3, leakage protection measures: the use of fixed potential grounding device.
4, on the basis of the original ordinary pump, according to the requirements of the fountain dedicated pump, the company after several tests, in the technical development, continuous improvement of processing materials, fountain dedicated pump can be frequent start, completely suitable for the use of music fountain.
5, the pump with stainless steel filter cover, three-phase four-wire cable.
6, stainless steel fountain pump for automatic water injection function.
7, the motor is self-circulating water-cooled.
Fountain submersible pump is mainly used for fountain water supply, aquaculture and other places. Widely used in low-lift cities, farmland irrigation and drainage, sprinkler irrigation, industrial and civil supply and drainage systems, hills, mountain water diversion, and low-lying areas to remove water.
2017年2月16日星期四
Hot water well submersible pump supporting high temperature cable selection
The specifications of the power cable with the hot water well submersible pump motor are determined by the heating and voltage drop of the cable. In addition to the need to control a certain current density to limit the cable temperature, the longer the length of the cable, the greater the voltage drop of the cable, the motor starting performance, performance and reliability of the greater impact. Therefore, the same with the two sets of diving motor, when equipped with hot water submersible pump head different, with different cable length, the requirements of the cable cross-section is not the same. In accordance with GB / T2816 "well submersible pump" standard, the water temperature is 25%, the current rating, the cable voltage drop should be ≤ 5% of the rated voltage. Which can be obtained when the power supply voltage is 380V, different power wells with hot water submersible pump motor with a certain size of the cable when the maximum allowable length. When the power supply voltage is higher and more stable or relatively large capacity of the power supply transformer, the voltage is high, more stable, the submersible pump motor with the same length of the cable to allow the appropriate length of the appropriate length Or with the cable cross-section appropriate to reduce the cable to reduce the cost of configuration) at this time with the submersible motor with the maximum allowable length of the cable, when the well with hot water submersible pump head is very high, the motor down well, with Cable length is longer, and the transformer power supply quality is poor, the motor starting is very difficult: starting current is very large, long cable voltage drop is very large, so that the motor terminal voltage is much lower, the starting current is further increased, the cable pressure drop , The starting torque is lower, resulting in a vicious bang, not only the motor starting difficult, forced start may cause electric = machine winding damage. At this time, in addition to the provisions of the cable should be configured, it is best to increase the transformer supply voltage.
The working principle and characteristics of fountain pump
The working principle and characteristics of fountain pump
1, the working principle of the fountain pump
Before the start of the fountain submersible pump, the pump and inlet pipe filled with water, pump operation, the high-speed rotation of the impeller generated by the centrifugal force, the impeller flow of water was thrown around, into the volute, impeller inlet to form a vacuum , The pool of water at the outside world pressure along the suction pipe was sucked to add this space. And then inhaled water and by the impeller by the volute and into the outlet pipe. It can be seen, if the centrifugal pump impeller constantly rotating, you can continue to absorb water, water, water can continue from low to high or distant. In summary, the fountain pump is due to the high-speed rotation of the impeller generated by the centrifugal force, the water phase of the high.
2, the general characteristics of the fountain pump
(1) The flow direction of the water along the fountain is in the axial direction of the impeller, perpendicular to the axial flow, that is, the direction of the incoming and outgoing water is 90 °.
(2) because the fountain pump impeller inlet to form a vacuum suction, so before the start of the pump and the suction pipe must be filled with water, or vacuum pump to evacuate the air to form a vacuum, and pump shell and suction pipe must be strictly sealed, Do not leak, otherwise the shape is not a vacuum, it can not absorb the water to.
1, the working principle of the fountain pump
Before the start of the fountain submersible pump, the pump and inlet pipe filled with water, pump operation, the high-speed rotation of the impeller generated by the centrifugal force, the impeller flow of water was thrown around, into the volute, impeller inlet to form a vacuum , The pool of water at the outside world pressure along the suction pipe was sucked to add this space. And then inhaled water and by the impeller by the volute and into the outlet pipe. It can be seen, if the centrifugal pump impeller constantly rotating, you can continue to absorb water, water, water can continue from low to high or distant. In summary, the fountain pump is due to the high-speed rotation of the impeller generated by the centrifugal force, the water phase of the high.
2, the general characteristics of the fountain pump
(1) The flow direction of the water along the fountain is in the axial direction of the impeller, perpendicular to the axial flow, that is, the direction of the incoming and outgoing water is 90 °.
(2) because the fountain pump impeller inlet to form a vacuum suction, so before the start of the pump and the suction pipe must be filled with water, or vacuum pump to evacuate the air to form a vacuum, and pump shell and suction pipe must be strictly sealed, Do not leak, otherwise the shape is not a vacuum, it can not absorb the water to.
Knowledge of fountain pump belts
Old models of fountain pumps generally use ordinary V-belt, and the new model of the fountain pump may use a serpentine belt. If the old model of the fountain pump installed in the new models, there may be some problems. Because the serpentine belt may drive the fountain submersible pump impeller in the opposite direction with the V-belt, thus causing the fountain pump to rotate in the reverse direction, resulting in overheating of the coolant.
Now more and more engines use the timing wheel of the camshaft to drive the fountain pump. The advantage of this is that the fountain pump does not rotate, and the car can not be driven and the engine length can be shortened. It must be emphasized that after a suitable period of time, the timing belt should be replaced. Sometimes see such a situation. The fountain pump is damaged in a very short time after installing a new timing belt, which is generally due to increased belt tension. Therefore, when installing a new pump, do not rush to switch to a new belt.
2017年2月15日星期三
Prevention Measures of Centrifugal Pump Vibration and Its Solution
Centrifugal pump vibration control, centrifugal pump vibration solution
① centrifugal pump vibration control from the design control
A. To improve the rigidity of the centrifugal pump, rigidity to control the vibration and improve the pump running invariance is very important. Which is the main point is to properly increase the pump shaft diameter and improve the pump seat rigidity. Increasing the rigidity of the pump requires that the pump be connected to the smallest rotor deflection during a permanent operation, and increasing the rigidity of the pump shaft helps to reduce the rotor deflection and improve the operational invariance. During the operation of the axis of the swing, destruction of sealing, wear ring and many other failures are not related to the rigidity of the shaft. Pump in addition to the strength of the calculation, the stiffness of the calculation can not be missing.
B. Considering the hydraulic design of the impeller The impeller of the pump should be subjected to cavitation and dewatering as little as possible during operation. In order to reduce the pulsating pressure, it is desirable to design the blade in a sloping form.
C. Strict requirements of the impeller static balance data centrifugal pump impeller static balance error value is generally the impeller diameter multiplied by 0.025g / mm, for high-speed impeller (2970r / min above), the static balance error should be reduced by half.
D. Designed with better bearing layout The design of the bearing housing should be better in the form of a bracket. At present, the cantilevered bearing frame is operated, and it seems that the layout is compact and small in size, but the rigidity is insufficient, the vibration resistance is poor and the failure rate is high during operation. The use of bracket-type pump seat can not only improve the rigidity of the support, and can save the pump shell by the manipulation of corrosion-resistant precious metal materials, that is, the pump casing can be thinned wall thickness, to balance their beauty.
E. Robust and reliable board design Some mobile-operated pumps are not very demanding on the root plate because the pump's inlet and outlet pipes are rubber hose and the ISG pipeline pump is in a free condition during operation. And in the process of fixed operation of the pump is often associated with the complex and strong steel pipe in the same way, the pipeline assembly stress, thermal expansion and contraction of the stress and deformation of the ultimate impact on the pump in the fundamental, The design should have sufficient strength and size requirements, for the direct form of the idea of low-speed pump, mechanical weight should be more than 3 times, high-speed pump was more than 5 times.
② centrifugal pump vibration control from the manufacturing quality control
A. Coaxiality should meet the requirements of a lot of vibration or failure of the pump is due to coaxial imbalance caused by coaxial degree of pumping all the rotating parts, such as IS centrifugal pump shaft, bearing, Impeller, pump shell and bearing accuracy, which are required by the design drawings marked with the accuracy of processing to ensure inspection.
B. Smooth manufacturing of impeller and pump shaft pump shaft Overview of the finish to be high, especially the seal and oil seal parts. Pump shaft heat treatment quality should meet the requirements, high speed pump should be more demanding. Impeller of the flow surface should be as smooth as possible, the material distribution should be average, the line should be accurate.
③ centrifugal pump vibration control from the installation of the first way to prevent and control pump vibration
A. The basic plate to find the right horn should choose the output point, the best set in the fundamental and symmetrical placement, the number of horns can not be more than three. Horn placed discomfort At that time, preloading bolts may cause deformation of the root plate.
B. Pump shaft and the motor shaft to ensure coaxial degree of coaxial coaxial axis, should be from the upper and lower and the object of the target off the calibration. Between the two shafts should be left between the required clearance to ensure that the two axes in the course of the operation to do limited axial movement.
C. Pipes should be equipped with a reasonable pump should be to avoid the sudden flow of the pipe and the backlog of air, the entrance is best equipped with a cone-shaped tapered pipe, so that the fluid inhalation gradually shorten the growth rate, so that the fluid into the average impeller.
D. Should be designed to avoid the impact of pipe stress on the pump pipe configuration equipment should be avoided as much as possible when the assembly stress, deformation stress and pipe valve gravity to the pump body, the greater the temperature difference between the pipe system should be set to metal spring Hose to eliminate the influence of pipe thermal stress. E. Check the root bolt is smooth and reliable After the new pump is installed, it is necessary to preload the anchor bolts and then test machine. If this is a matter of neglect, often resulting in the underlying plate under the oblique horn vibration and abdication, and then tightly destroy the level of the fundamental board, which will cause long-term adverse effects on the operation of the pump.
(3) Centrifugal pump vibration solution from the operation and maintenance to solve the pump vibration
① as far as possible the use of low-speed pump Although the high-speed pump can reduce the size of the pump and improve efficiency, but some high-speed pump because of the design and manufacturing problems difficult to comply with the requirements of high-speed operation, poor operation, Therefore, from the operational considerations, in order to reduce the loss of downtime and delay the operating life, or use low-speed pump is more favorable.
② to prevent the operation of small flow or open air pump operation is not allowed to manipulate the import valve to adjust the amount of energy, the operating conditions of the general import valve should be fully open, control the flow can only adjust the export valve, if the operation of the valve long lasting off Pump capacity is too large, running is not economical and affect the life, be careful to change the pump or reduce the speed of running low-speed centrifugal pump.
③ The pump is sealed in a sealed condition. In addition to the leakage caused by running the drip, the most serious problem is that the fluid enters the bearing interior, exacerbates wear, causes vibration and shortens the life. When the packing letter (packing) is applied, in addition to the usual operational requirements, the most easily overlooked problem is to fill the stuffing box. The roundabout groove on the sleeve is often caused by the incorporation of a dirty packing with a sticky soil and sand. If it is to use mechanical seals, the need to pay attention to the problem is moving, static ring material selection summary appropriate, the material can not be offset by the erosion of the working medium, mechanical seal is one of the main factors of multiple failures.
④ strict inspection of the pump running and real-time processing
Check oil temperature and temperature rise of lubricating oil.
B. Check the temperature and leakage of the stuffing part.
C. Check the vibration and abnormal noise. ,
D. To pay attention to the discharge port, suction teeth pressure changes and flow changes, discharge pressure changes violently or decline, often because the suction side of the foreign body is blocked or inhaled the air, to stop the pump in real time.
E. Check the operation of the idea and often pay attention to watch the ammeter pointer fluctuations, the daily inspection of the contents of the contents of the best recorded in the file, found abnormal circumstances should be real-time shutdown, not a delay.
① centrifugal pump vibration control from the design control
A. To improve the rigidity of the centrifugal pump, rigidity to control the vibration and improve the pump running invariance is very important. Which is the main point is to properly increase the pump shaft diameter and improve the pump seat rigidity. Increasing the rigidity of the pump requires that the pump be connected to the smallest rotor deflection during a permanent operation, and increasing the rigidity of the pump shaft helps to reduce the rotor deflection and improve the operational invariance. During the operation of the axis of the swing, destruction of sealing, wear ring and many other failures are not related to the rigidity of the shaft. Pump in addition to the strength of the calculation, the stiffness of the calculation can not be missing.
B. Considering the hydraulic design of the impeller The impeller of the pump should be subjected to cavitation and dewatering as little as possible during operation. In order to reduce the pulsating pressure, it is desirable to design the blade in a sloping form.
C. Strict requirements of the impeller static balance data centrifugal pump impeller static balance error value is generally the impeller diameter multiplied by 0.025g / mm, for high-speed impeller (2970r / min above), the static balance error should be reduced by half.
D. Designed with better bearing layout The design of the bearing housing should be better in the form of a bracket. At present, the cantilevered bearing frame is operated, and it seems that the layout is compact and small in size, but the rigidity is insufficient, the vibration resistance is poor and the failure rate is high during operation. The use of bracket-type pump seat can not only improve the rigidity of the support, and can save the pump shell by the manipulation of corrosion-resistant precious metal materials, that is, the pump casing can be thinned wall thickness, to balance their beauty.
E. Robust and reliable board design Some mobile-operated pumps are not very demanding on the root plate because the pump's inlet and outlet pipes are rubber hose and the ISG pipeline pump is in a free condition during operation. And in the process of fixed operation of the pump is often associated with the complex and strong steel pipe in the same way, the pipeline assembly stress, thermal expansion and contraction of the stress and deformation of the ultimate impact on the pump in the fundamental, The design should have sufficient strength and size requirements, for the direct form of the idea of low-speed pump, mechanical weight should be more than 3 times, high-speed pump was more than 5 times.
② centrifugal pump vibration control from the manufacturing quality control
A. Coaxiality should meet the requirements of a lot of vibration or failure of the pump is due to coaxial imbalance caused by coaxial degree of pumping all the rotating parts, such as IS centrifugal pump shaft, bearing, Impeller, pump shell and bearing accuracy, which are required by the design drawings marked with the accuracy of processing to ensure inspection.
B. Smooth manufacturing of impeller and pump shaft pump shaft Overview of the finish to be high, especially the seal and oil seal parts. Pump shaft heat treatment quality should meet the requirements, high speed pump should be more demanding. Impeller of the flow surface should be as smooth as possible, the material distribution should be average, the line should be accurate.
③ centrifugal pump vibration control from the installation of the first way to prevent and control pump vibration
A. The basic plate to find the right horn should choose the output point, the best set in the fundamental and symmetrical placement, the number of horns can not be more than three. Horn placed discomfort At that time, preloading bolts may cause deformation of the root plate.
B. Pump shaft and the motor shaft to ensure coaxial degree of coaxial coaxial axis, should be from the upper and lower and the object of the target off the calibration. Between the two shafts should be left between the required clearance to ensure that the two axes in the course of the operation to do limited axial movement.
C. Pipes should be equipped with a reasonable pump should be to avoid the sudden flow of the pipe and the backlog of air, the entrance is best equipped with a cone-shaped tapered pipe, so that the fluid inhalation gradually shorten the growth rate, so that the fluid into the average impeller.
D. Should be designed to avoid the impact of pipe stress on the pump pipe configuration equipment should be avoided as much as possible when the assembly stress, deformation stress and pipe valve gravity to the pump body, the greater the temperature difference between the pipe system should be set to metal spring Hose to eliminate the influence of pipe thermal stress. E. Check the root bolt is smooth and reliable After the new pump is installed, it is necessary to preload the anchor bolts and then test machine. If this is a matter of neglect, often resulting in the underlying plate under the oblique horn vibration and abdication, and then tightly destroy the level of the fundamental board, which will cause long-term adverse effects on the operation of the pump.
(3) Centrifugal pump vibration solution from the operation and maintenance to solve the pump vibration
① as far as possible the use of low-speed pump Although the high-speed pump can reduce the size of the pump and improve efficiency, but some high-speed pump because of the design and manufacturing problems difficult to comply with the requirements of high-speed operation, poor operation, Therefore, from the operational considerations, in order to reduce the loss of downtime and delay the operating life, or use low-speed pump is more favorable.
② to prevent the operation of small flow or open air pump operation is not allowed to manipulate the import valve to adjust the amount of energy, the operating conditions of the general import valve should be fully open, control the flow can only adjust the export valve, if the operation of the valve long lasting off Pump capacity is too large, running is not economical and affect the life, be careful to change the pump or reduce the speed of running low-speed centrifugal pump.
③ The pump is sealed in a sealed condition. In addition to the leakage caused by running the drip, the most serious problem is that the fluid enters the bearing interior, exacerbates wear, causes vibration and shortens the life. When the packing letter (packing) is applied, in addition to the usual operational requirements, the most easily overlooked problem is to fill the stuffing box. The roundabout groove on the sleeve is often caused by the incorporation of a dirty packing with a sticky soil and sand. If it is to use mechanical seals, the need to pay attention to the problem is moving, static ring material selection summary appropriate, the material can not be offset by the erosion of the working medium, mechanical seal is one of the main factors of multiple failures.
④ strict inspection of the pump running and real-time processing
Check oil temperature and temperature rise of lubricating oil.
B. Check the temperature and leakage of the stuffing part.
C. Check the vibration and abnormal noise. ,
D. To pay attention to the discharge port, suction teeth pressure changes and flow changes, discharge pressure changes violently or decline, often because the suction side of the foreign body is blocked or inhaled the air, to stop the pump in real time.
E. Check the operation of the idea and often pay attention to watch the ammeter pointer fluctuations, the daily inspection of the contents of the contents of the best recorded in the file, found abnormal circumstances should be real-time shutdown, not a delay.
Installation Requirements and Operation Method of Deep Well Submersible Pump
Deep well pump installation requirements, deep well pump operation method
(1) installation requirements for deep well pumps
① This provision applies to the installation of long shaft deep well pumps and submersible pumps.
② Deep well pump cleaning and inspection should meet the following requirements: parts and parts of all the mating surface (thread, stop, end, etc.) should be clean and clean; factory assembled parts should not be dismounted j working parts (rotating part) The rotation should be flexible.
③ before the pump in place should be the following checks: well pipe diameter and well pipe straightness should be consistent with the provisions of the equipment technical documents, pump sets of wells in the well part of the wells should be free up and down, submersible pumps shall not damage the diving cable; (Figure 2-1); between the well pipe and the foundation should be placed on the soft isolation layer; the middle of the middle of the middle of the size of the gap should be consistent with the requirements of the connection between the pump and pump seat ; Pipe should be no sludge and sludge; salt pipe should be straight, threaded and flange surface should be no bruises, and should be clean and clean.
Long shaft deep well pump should be checked according to the following requirements: the working parts should be flexible rotation, the impeller shaft axial flow should be consistent with the provisions of the equipment technical documents; pump drive shaft end should be flat, end and thread should be no damage, and Should be clean and clean, the drive shaft at both ends of the case of support, the central radial runout should not be greater than 0.2ram; bearing bearings and rubber bearings should be intact, rubber bearings should not be contaminated with grease.
(2) the operation of deep well pump
① The operator must master the general part of the operating procedures.
② open pump operation: deep well submersible pump should be opened before the start of the release valve, and then shut, start the outlet valve should not be closed, can be slightly open some, to be opened immediately after the start, control to the appropriate location, submersible pump running smoothly Open the pressure gauge valve; submersible pump operation, observe the ammeter and voltmeter instructions whether there is a significant change in the operation of whether the noise, the normal working current should not be greater than the motor nameplate on the specified rating; pump should be within the specified flow range Use, the pump flow must not be too large, too large or too small should be appropriate to adjust the opening of the outlet valve; one of the following circumstances should immediately stop running, the pump working state has not changed, the voltage rating and current exceeds the rated value , The pump intermittent water, the water pipe has a significant vibration, issued a loud noise, frequent switching switch protection.
③ stop the pump: stop the pump operation, close the outlet valve and pressure gauge valve; pump stop, in order to reduce the water back, should cut off the circuit, turn off the valve; if restart, after 5min or more get on.
(1) installation requirements for deep well pumps
① This provision applies to the installation of long shaft deep well pumps and submersible pumps.
② Deep well pump cleaning and inspection should meet the following requirements: parts and parts of all the mating surface (thread, stop, end, etc.) should be clean and clean; factory assembled parts should not be dismounted j working parts (rotating part) The rotation should be flexible.
③ before the pump in place should be the following checks: well pipe diameter and well pipe straightness should be consistent with the provisions of the equipment technical documents, pump sets of wells in the well part of the wells should be free up and down, submersible pumps shall not damage the diving cable; (Figure 2-1); between the well pipe and the foundation should be placed on the soft isolation layer; the middle of the middle of the middle of the size of the gap should be consistent with the requirements of the connection between the pump and pump seat ; Pipe should be no sludge and sludge; salt pipe should be straight, threaded and flange surface should be no bruises, and should be clean and clean.
Long shaft deep well pump should be checked according to the following requirements: the working parts should be flexible rotation, the impeller shaft axial flow should be consistent with the provisions of the equipment technical documents; pump drive shaft end should be flat, end and thread should be no damage, and Should be clean and clean, the drive shaft at both ends of the case of support, the central radial runout should not be greater than 0.2ram; bearing bearings and rubber bearings should be intact, rubber bearings should not be contaminated with grease.
(2) the operation of deep well pump
① The operator must master the general part of the operating procedures.
② open pump operation: deep well submersible pump should be opened before the start of the release valve, and then shut, start the outlet valve should not be closed, can be slightly open some, to be opened immediately after the start, control to the appropriate location, submersible pump running smoothly Open the pressure gauge valve; submersible pump operation, observe the ammeter and voltmeter instructions whether there is a significant change in the operation of whether the noise, the normal working current should not be greater than the motor nameplate on the specified rating; pump should be within the specified flow range Use, the pump flow must not be too large, too large or too small should be appropriate to adjust the opening of the outlet valve; one of the following circumstances should immediately stop running, the pump working state has not changed, the voltage rating and current exceeds the rated value , The pump intermittent water, the water pipe has a significant vibration, issued a loud noise, frequent switching switch protection.
③ stop the pump: stop the pump operation, close the outlet valve and pressure gauge valve; pump stop, in order to reduce the water back, should cut off the circuit, turn off the valve; if restart, after 5min or more get on.
Method of Adjusting Performance of Axial Flow Pump
Axial flow pump performance adjustment methods are variable angle adjustment and variable speed adjustment of two, after we installed, if you do not meet the production requirements, you can use the following two ways to adjust the pump performance.
1, variable angle adjustment; from the structure point of view, axial flow pump impeller has a huge hub, easy to install adjustable angle of the blade. When the blade installation angle changes, the blade of the water lift also changed, thus changing the performance of the pump, which is the axial flow pump variable angle adjustment. As the blade mounting angle increases or becomes smaller, the flow rate of the axial flow pump, the head, the power changes, but the highest point of efficiency does not change, it is very advantageous to the axial pump performance adjustment.
2, variable speed adjustment; axial flow pump is working at a certain speed, and at a certain speed to obtain the appropriate flow, head, power and efficiency. When the speed changes, its performance parameters are also corresponding changes, so as to achieve the purpose of regulation. If the axial flow pump is powered by a diesel engine or a gasoline engine, it can change the size of the accelerator to change the speed. If the axial flow pump is connected with the power machine is a delta belt or flat belt indirect transmission device, you can change the transmission pulley diameter to change, Wheel or driven wheel can be, the purpose of foot to change the transmission ratio. Variable speed pump performance is more economical, wide range of applications, all agricultural pumps can be used.
1, variable angle adjustment; from the structure point of view, axial flow pump impeller has a huge hub, easy to install adjustable angle of the blade. When the blade installation angle changes, the blade of the water lift also changed, thus changing the performance of the pump, which is the axial flow pump variable angle adjustment. As the blade mounting angle increases or becomes smaller, the flow rate of the axial flow pump, the head, the power changes, but the highest point of efficiency does not change, it is very advantageous to the axial pump performance adjustment.
2, variable speed adjustment; axial flow pump is working at a certain speed, and at a certain speed to obtain the appropriate flow, head, power and efficiency. When the speed changes, its performance parameters are also corresponding changes, so as to achieve the purpose of regulation. If the axial flow pump is powered by a diesel engine or a gasoline engine, it can change the size of the accelerator to change the speed. If the axial flow pump is connected with the power machine is a delta belt or flat belt indirect transmission device, you can change the transmission pulley diameter to change, Wheel or driven wheel can be, the purpose of foot to change the transmission ratio. Variable speed pump performance is more economical, wide range of applications, all agricultural pumps can be used.
how to deal with mine submersible pump pump pipe fittings leakage
Daily use of mine submersible pumps in the process, we sometimes in the water pipe joints, connecting bolts, observed the phenomenon of leakage. The main reason: water pipe failure, defective, did not do the pressure test; installation of the pipeline process, the gasket is not put, the connector is not handled well, the coupling bolt is not even tightened. In response to these problems, we have to repair or even replace the defective pipes, tear off or re-arrange those centers that deviate from the larger butt joints. After aligning the hole, insert the coupling bolts into the tightening. After installing the complete piping, the pressure and the leakage test of the system are carried out.
In addition, due to mine submersible pump leakage will lead to insulation damage, bearing flooding, so that the unit to stop running, we should strengthen this precaution. The main reasons for the leakage of the pump include mechanical seal or cable inlet special seal, 0 type ring is damaged, power cable or signal cable is damaged; under normal circumstances, the protection device will promptly issued flooding, leakage, humidity and other alarm signals, Stop.
In order to avoid the phenomenon of pump leakage, before the installation, check the motor surface with or without water leakage phenomenon, and check the quality of the sealing parts; installation must ensure that the sealing parts of the end contact is good; check the motor before and check the insulation and grounding insulation resistance and Alarm system sensor components are intact. Found in the operation of water leakage, the need to remove the relevant seals and damaged cable, put on a new.
In addition, due to mine submersible pump leakage will lead to insulation damage, bearing flooding, so that the unit to stop running, we should strengthen this precaution. The main reasons for the leakage of the pump include mechanical seal or cable inlet special seal, 0 type ring is damaged, power cable or signal cable is damaged; under normal circumstances, the protection device will promptly issued flooding, leakage, humidity and other alarm signals, Stop.
In order to avoid the phenomenon of pump leakage, before the installation, check the motor surface with or without water leakage phenomenon, and check the quality of the sealing parts; installation must ensure that the sealing parts of the end contact is good; check the motor before and check the insulation and grounding insulation resistance and Alarm system sensor components are intact. Found in the operation of water leakage, the need to remove the relevant seals and damaged cable, put on a new.
Mine submersible pump shaft and bearing inspection and assembly
Under normal circumstances, the mine submersible pump journal can not have scars, journal cylindrical cylinder tolerance value of 0.0lmm; gear pump after a period of time, the maximum wear of the journal shall not be greater than 0.01D.
Mine submersible pump bearings generally use both rolling bearings and plain bearings, and sliding bearings for the form of copper sets. The use of rolling bearing gear pump bearing inner ring and the shaft with the H7 / js6; needle roller bearings without inner ring, the shaft and the needle with the H7 / h6; needle roller bearing outer ring and the cover with the K7 / H6, the use of sliding bearing mining pump bearing bore and cylindrical coaxial degree tolerance of 0. 01 mm; sliding bearing outer and end cover with R7 / h6;
Gear pump bearing wear should be replaced after the super-standard, rolling bearing assembly method and centrifugal pump rolling bearing assembly method is the same. With copper sleeve for the bearing gear pump, in the replacement of copper sets, the first should check the copper sleeve and the cover with the situation. In compliance with the requirements, the copper sleeve coated with oil, with a press to press it into the pump cover body, and finally in the bearing and end cap interface drilling thread with screws to fix it, to prevent copper sets Rotation or axial movement.
Copper sleeve assembly must be checked after the journal and copper sleeve with the gap, if the gap is too small, should be based on the journal, scraping copper sets, until meet the requirements so far. On the contrary, if the gap is too large to re-replace the copper sleeve.
Mine submersible pump bearings generally use both rolling bearings and plain bearings, and sliding bearings for the form of copper sets. The use of rolling bearing gear pump bearing inner ring and the shaft with the H7 / js6; needle roller bearings without inner ring, the shaft and the needle with the H7 / h6; needle roller bearing outer ring and the cover with the K7 / H6, the use of sliding bearing mining pump bearing bore and cylindrical coaxial degree tolerance of 0. 01 mm; sliding bearing outer and end cover with R7 / h6;
Gear pump bearing wear should be replaced after the super-standard, rolling bearing assembly method and centrifugal pump rolling bearing assembly method is the same. With copper sleeve for the bearing gear pump, in the replacement of copper sets, the first should check the copper sleeve and the cover with the situation. In compliance with the requirements, the copper sleeve coated with oil, with a press to press it into the pump cover body, and finally in the bearing and end cap interface drilling thread with screws to fix it, to prevent copper sets Rotation or axial movement.
Copper sleeve assembly must be checked after the journal and copper sleeve with the gap, if the gap is too small, should be based on the journal, scraping copper sets, until meet the requirements so far. On the contrary, if the gap is too large to re-replace the copper sleeve.
Stainless steel fountain pump vibration how to deal with?
Stainless steel fountain pump is the use of motor-driven centrifugal force to gradually introduce some of the liquid surface of the equipment, in the manufacture of fountains for people at the same time, but also for the surrounding environment to add a beautiful landscape. Stainless steel fountain pump selection is also a skill, improper selection and operation error is likely to cause vibration occurred Oh. So, what are the potential causes of fountain pump vibration is how to deal with it? Here we stainless steel fountain pump experts give some advice on the corresponding solution:
Two pumps in parallel should ensure that the pump performance is the same. Pump performance curve should be slow down type as well, can not have hump.
Regularly need to fill the oil bearing the appropriate amount of oil, for the long axis of liquid centrifugal pump, because the shaft there is a torsional vibration, if the use of a thrust tile, the damage is mainly thrust tile, then you can properly increase the viscosity of lubricating oil , To prevent the destruction of liquid dynamic pressure lubricating film.
Note: Eliminate the factors that lead to overloading the stainless steel fountain pump, such as the runner blockage; extend the pump's start time properly, reduce the disturbance to the drive shaft, reduce the collision and friction between the rotating parts and the stationary parts, The heat caused by the deformation; for water lubricated sliding bearings, start the process should be added pre-run water, to avoid dry start until the water pump and then stop the water.
Stainless steel fountain pump It is recommended to use the measurement and analysis vibration conditions to determine the optimum operating parameters of the pump in order to prevent the amplitude of the stainless steel fountain pump from being too large.
Two pumps in parallel should ensure that the pump performance is the same. Pump performance curve should be slow down type as well, can not have hump.
Regularly need to fill the oil bearing the appropriate amount of oil, for the long axis of liquid centrifugal pump, because the shaft there is a torsional vibration, if the use of a thrust tile, the damage is mainly thrust tile, then you can properly increase the viscosity of lubricating oil , To prevent the destruction of liquid dynamic pressure lubricating film.
Note: Eliminate the factors that lead to overloading the stainless steel fountain pump, such as the runner blockage; extend the pump's start time properly, reduce the disturbance to the drive shaft, reduce the collision and friction between the rotating parts and the stationary parts, The heat caused by the deformation; for water lubricated sliding bearings, start the process should be added pre-run water, to avoid dry start until the water pump and then stop the water.
Stainless steel fountain pump It is recommended to use the measurement and analysis vibration conditions to determine the optimum operating parameters of the pump in order to prevent the amplitude of the stainless steel fountain pump from being too large.
Fountain pump attention points during disassembly
Fountain pumps can be seen everywhere in our real life, a device that can go fountains and see the fountain pump in every part of the world. It's an important fountain pump to get a popular welcome The reason people use the fountain pump fountain to get happiness, the same use of fountain pump to relax their body and mind. Here to explain the fountain pump in the demolition of attention to points.
Check the fountain Submersible pump bearings: check the motor part of the upper and lower bearings, if found wear or clearance is too large, to be timely replacement of new bearings, is strictly prohibited "sick" improvised use.
Check the following:
If the motor is running, the submersible pump produces a "click" sound, and the cycle is proportional to the speed, and the hand when the rotor is laborious, bearing raceway is a bit astringent or avulsion phenomenon; if the bearing issued intermittent " Choked choked "sound, the rotor when the rotor is uncertain when the dead point, the general is a submersible pump ball frame damage, broken inner ring or broken ball. Encountered the above situation, you must replace the bearings, so as to avoid greater damage.
Submersible pump should be marked before the front and rear cover and the base of the seat. In order to repair the assembly by the original assembly, it will not cause the assembly error caused by the shaft is different from the heart; in the demolition submersible pump impeller and sleeve and other components, it should be noted that do not hard hard punch, the principle of thermal expansion, Edge tapping or "Rama" and other tools to remove.
Check the fountain Submersible pump bearings: check the motor part of the upper and lower bearings, if found wear or clearance is too large, to be timely replacement of new bearings, is strictly prohibited "sick" improvised use.
Check the following:
If the motor is running, the submersible pump produces a "click" sound, and the cycle is proportional to the speed, and the hand when the rotor is laborious, bearing raceway is a bit astringent or avulsion phenomenon; if the bearing issued intermittent " Choked choked "sound, the rotor when the rotor is uncertain when the dead point, the general is a submersible pump ball frame damage, broken inner ring or broken ball. Encountered the above situation, you must replace the bearings, so as to avoid greater damage.
Submersible pump should be marked before the front and rear cover and the base of the seat. In order to repair the assembly by the original assembly, it will not cause the assembly error caused by the shaft is different from the heart; in the demolition submersible pump impeller and sleeve and other components, it should be noted that do not hard hard punch, the principle of thermal expansion, Edge tapping or "Rama" and other tools to remove.
How to improve the running life of hot water submersible pumps
How to improve the running life of hot water submersible pumps
(1), hot water submersible pump population piping should be sealed well, hot water submersible pumps generally have good self-absorption performance, in the course of work, the population pressure to negative pressure, bad seal leading to air into, Resulting in increased noise vibration of the pump, damage to the pump rotor parts, hot water submersible pump life.
(2), hot water submersible pump at the beginning of the start, no pressure in the export formation, do not blindly speed to prevent shaft or bearing premature damage.
(3), hot water submersible pump outlet pressure measurement points to set up interlock to stop the alarm, otherwise, once the discharge pipe blocked, easy to cause the pump body is bad.
(4), for high viscosity hot water submersible pumps, easy to crystal pump, in the system should be set up Tt parking cleaning system, so that after the pump will be easy to clear the pump outside the pump, to prevent the crystallization in the pump, start up.
(5), cleaning pipetting, do not use hot water submersible pump pump delivery cleaning fluid, should remove the inner parts, after the end of the installation of fluid, so as not to pump inside the stick foreign body.
(6), for high temperature submersible pumps, because the pump at high temperature operation, the temperature will be shifted after the transfer, so the installation of the cold pipe should be set on the hinge seat, which can effectively prevent the temperature after the pipe displacement.
(7), for high temperature submersible pumps, couplings must be hot after the pump heat correction, in order to avoid additional torque caused by operation.
(8), the pump heat medium jacket temperature should be slightly lower than the front and rear jacket tube heat medium temperature. Because the melt viscosity and shear rate into a decreasing function, the gear squeeze, bearing the shear will melt temperature through the pump after the rise of 3 ℃ -5 ℃, reduce the heat medium temperature to prevent melt degradation.
(9), speed to slow, do not make the sharp rise in pressure before and after, so as not to damage the bearing or make the melt plugging lubrication ring Road.
(10), hot water submersible pump outlet filter to be replaced regularly, so as not to plug the outlet. The pump long-term operation under high pressure.
(11), should be replaced regularly. When the hot water submersible pump due to the bearing gap becomes larger and larger when the voice should be replaced. Of course, the bearings can be re-used to re-use the bearing after alloying.
(1), hot water submersible pump population piping should be sealed well, hot water submersible pumps generally have good self-absorption performance, in the course of work, the population pressure to negative pressure, bad seal leading to air into, Resulting in increased noise vibration of the pump, damage to the pump rotor parts, hot water submersible pump life.
(2), hot water submersible pump at the beginning of the start, no pressure in the export formation, do not blindly speed to prevent shaft or bearing premature damage.
(3), hot water submersible pump outlet pressure measurement points to set up interlock to stop the alarm, otherwise, once the discharge pipe blocked, easy to cause the pump body is bad.
(4), for high viscosity hot water submersible pumps, easy to crystal pump, in the system should be set up Tt parking cleaning system, so that after the pump will be easy to clear the pump outside the pump, to prevent the crystallization in the pump, start up.
(5), cleaning pipetting, do not use hot water submersible pump pump delivery cleaning fluid, should remove the inner parts, after the end of the installation of fluid, so as not to pump inside the stick foreign body.
(6), for high temperature submersible pumps, because the pump at high temperature operation, the temperature will be shifted after the transfer, so the installation of the cold pipe should be set on the hinge seat, which can effectively prevent the temperature after the pipe displacement.
(7), for high temperature submersible pumps, couplings must be hot after the pump heat correction, in order to avoid additional torque caused by operation.
(8), the pump heat medium jacket temperature should be slightly lower than the front and rear jacket tube heat medium temperature. Because the melt viscosity and shear rate into a decreasing function, the gear squeeze, bearing the shear will melt temperature through the pump after the rise of 3 ℃ -5 ℃, reduce the heat medium temperature to prevent melt degradation.
(9), speed to slow, do not make the sharp rise in pressure before and after, so as not to damage the bearing or make the melt plugging lubrication ring Road.
(10), hot water submersible pump outlet filter to be replaced regularly, so as not to plug the outlet. The pump long-term operation under high pressure.
(11), should be replaced regularly. When the hot water submersible pump due to the bearing gap becomes larger and larger when the voice should be replaced. Of course, the bearings can be re-used to re-use the bearing after alloying.
Hot water submersible pump installation method?
Hot water submersible pump installation method?
(1) According to the hot water submersible pump spindle position can be divided into:
① vertical installation: (vertical) pump installed in the vertical direction of the spindle, the installation of the bracket. The vertical installation of the pump is limited by the working environment of the pump (eg piping pumps, submerged pumps, deep well pumps, drum pumps, hot water submersible pumps), installation space constraints (vertical marine pumps) and design factors (eg vertical high speed Pump).
② Horizontal installation: The horizontal (horizontal) submersible pump installed in the horizontal direction of the spindle, the installation of the bracket, which is the installation of most pumps.
(2) by hot water submersible pump can be divided into:
① wet installation: the pump part or all installed in the liquid installation. This installation is compact, small footprint, installed directly in the sewage pool, no need to build a dedicated pump room to install pumps and motors, you can save a lot of land and infrastructure costs, easy installation and maintenance; but the pump seal Performance, insulation performance requirements.
② dry installation: the pump completely placed outside the installation of the liquid, which is the installation of most of the pump, with intuitive maintenance, size is appropriate, the lower requirements of the motor pump, the characteristics of strong adaptability.
(3) According to whether the submersible pump can be divided into:
① mobile installation: the pump or its components installed on a removable carrier (such as car) installation method. This installation method used in small, intermittent use, the use of more occasions.
② fixed installation: the pump fixed to the foundation or bracket on the installation, is the most commonly used installation.
(1) According to the hot water submersible pump spindle position can be divided into:
① vertical installation: (vertical) pump installed in the vertical direction of the spindle, the installation of the bracket. The vertical installation of the pump is limited by the working environment of the pump (eg piping pumps, submerged pumps, deep well pumps, drum pumps, hot water submersible pumps), installation space constraints (vertical marine pumps) and design factors (eg vertical high speed Pump).
② Horizontal installation: The horizontal (horizontal) submersible pump installed in the horizontal direction of the spindle, the installation of the bracket, which is the installation of most pumps.
(2) by hot water submersible pump can be divided into:
① wet installation: the pump part or all installed in the liquid installation. This installation is compact, small footprint, installed directly in the sewage pool, no need to build a dedicated pump room to install pumps and motors, you can save a lot of land and infrastructure costs, easy installation and maintenance; but the pump seal Performance, insulation performance requirements.
② dry installation: the pump completely placed outside the installation of the liquid, which is the installation of most of the pump, with intuitive maintenance, size is appropriate, the lower requirements of the motor pump, the characteristics of strong adaptability.
(3) According to whether the submersible pump can be divided into:
① mobile installation: the pump or its components installed on a removable carrier (such as car) installation method. This installation method used in small, intermittent use, the use of more occasions.
② fixed installation: the pump fixed to the foundation or bracket on the installation, is the most commonly used installation.
2017年2月14日星期二
The Law of Valve Movement of Fountain Pump
In the experiment, it was found that the movement law of the valve of the fountain pump was not exactly the same as that of the people, and its movement was accompanied by two kinds of rotary motion in addition to the linear motion in the vertical direction. When the plunger movement speed is small, the valve ball around the vertical axis of the horizontal rotation and along the hole in the seat hole that is the valve seat hole axis revolution. The angular velocity of the plunger is related to the velocity of the plunger. The greater the speed of the plunger, the greater the angular velocity of the ball. The special form of the ball is mainly related to the particularity of the valve ball, the seat structure and the impact of the fluid. Deep well pump is a spherical valve, when the fluid around it flows, in the back of the surface layer will be off the phenomenon, while generating a lateral excitation force. Due to the symmetry of the ball, this lateral force will move along the circumference of the "equator" around the ball, so that the ball is not always on the axis of the valve seat, but away from a distance and close to the seat Corner on the rotation, which is the "revolution" phenomenon.
In addition, due to the instability of the fluid flow and the deviation of the ball caused by the fluid relative to the valve ball flow asymmetry, the ball will produce a certain degree of deflection, so that the lateral force is not acting on the core, but in the horizontal There is a certain eccentric, so that the ball in the horizontal plane there is a rotation, that is, "rotation" phenomenon. The above conclusion is obtained in the case of pure liquid. In the gas-liquid mixed-phase flow, due to the existence of bubbles, the flow field disturbance is more intense, and the bubble on the ball has a certain impact, this time the ball movement is more complex, in addition to rotating movement, there are drifting up and down.
In addition, due to the instability of the fluid flow and the deviation of the ball caused by the fluid relative to the valve ball flow asymmetry, the ball will produce a certain degree of deflection, so that the lateral force is not acting on the core, but in the horizontal There is a certain eccentric, so that the ball in the horizontal plane there is a rotation, that is, "rotation" phenomenon. The above conclusion is obtained in the case of pure liquid. In the gas-liquid mixed-phase flow, due to the existence of bubbles, the flow field disturbance is more intense, and the bubble on the ball has a certain impact, this time the ball movement is more complex, in addition to rotating movement, there are drifting up and down.
Fountain pump use precautions
Fountain pump is actually a well submersible pump, is designed for agricultural irrigation and drainage, sprinkler irrigation, industrial and civil construction of the drainage system developed for ponds, fish ponds, water towers, deep wells and high water delivery.
When using the fountain submersible pump, there are a few points that require special attention:
1, equipment grounding:
In order to ensure the safety of the fountain when used, the state of the mandatory requirements of the submersible pump is to take protective grounding, or once the pump shell leakage, water pump near the water and the reservoir surface will be charged, seriously endanger the safety of humans and animals , Will also cause the waste of electricity.
If the fountain pump metal shell and meet the national standard grounding (grounding resistance is not greater than 4Ω) ground connection, leakage, the current through the pump shell, ground, grounding, ground, transformer working ground wire and power to form a closed Circuit, once the leakage current is too large, is to make the pump protection device work - fuse blow or air switch trip, automatically disconnect the fountain pump power.
2, install the leakage protector:
Once the leakage crisis occurs, as long as the leakage value exceeds the operating current value of the leakage protector, usually not more than 30mA, the leakage protector will work, disconnect the switch, so that the fountain to stop running.
3, the power supply voltage is abnormal when the boot:
As a submersible pump, the voltage is too high, too low will make the pump temperature rise, shorten the life of the pump, or even burn, and now in many places there is a long-term low-voltage power supply line or line terminal voltage is too high, the terminal voltage is too low The problem. Therefore, when the fountain is running, the operator should always pay attention to the power supply voltage value, when the power supply voltage is higher than the rated voltage of 10% or less than the rated voltage of 10%, and the current exceeds the rated current of 20%, should immediately stop, to avoid abnormal voltage Boot.
4, the motor in the opposite direction of rotation:
Although some fountain submersible pumps can reverse the double water, but because of the reverse flow of small current, so reverse the time is too long will damage the motor.
5, to avoid long-term overload work
When using the fountain submersible pump, there are a few points that require special attention:
1, equipment grounding:
In order to ensure the safety of the fountain when used, the state of the mandatory requirements of the submersible pump is to take protective grounding, or once the pump shell leakage, water pump near the water and the reservoir surface will be charged, seriously endanger the safety of humans and animals , Will also cause the waste of electricity.
If the fountain pump metal shell and meet the national standard grounding (grounding resistance is not greater than 4Ω) ground connection, leakage, the current through the pump shell, ground, grounding, ground, transformer working ground wire and power to form a closed Circuit, once the leakage current is too large, is to make the pump protection device work - fuse blow or air switch trip, automatically disconnect the fountain pump power.
2, install the leakage protector:
Once the leakage crisis occurs, as long as the leakage value exceeds the operating current value of the leakage protector, usually not more than 30mA, the leakage protector will work, disconnect the switch, so that the fountain to stop running.
3, the power supply voltage is abnormal when the boot:
As a submersible pump, the voltage is too high, too low will make the pump temperature rise, shorten the life of the pump, or even burn, and now in many places there is a long-term low-voltage power supply line or line terminal voltage is too high, the terminal voltage is too low The problem. Therefore, when the fountain is running, the operator should always pay attention to the power supply voltage value, when the power supply voltage is higher than the rated voltage of 10% or less than the rated voltage of 10%, and the current exceeds the rated current of 20%, should immediately stop, to avoid abnormal voltage Boot.
4, the motor in the opposite direction of rotation:
Although some fountain submersible pumps can reverse the double water, but because of the reverse flow of small current, so reverse the time is too long will damage the motor.
5, to avoid long-term overload work
Mine submersible pump which is good
Mine submersible pump is mainly used for coal mine central pumping station drainage, coal mine flood disaster after the rescue or drainage drainage, commonly used is a centrifugal pump. Mine submersible pumps are commonly used D-type, DA-type and TSW-type multi-stage centrifugal pump; and the bottom of the water and mining area drainage is commonly used B, BA and BZ single-stage centrifugal pump.
Mine submersible pump main working parts are impellers, which have a certain number of leaves, impeller fixed on the shaft, driven by the shaft rotation. The pump housing is a spiral diffusion chamber, the suction port of the pump is connected with the water absorption, and the drain is connected with the drain pipe.
Before the pump starts, the water is injected into the pump by the water injection funnel, and then the pump is started. The impeller rotates with the shaft. The water in the impeller is also rotated by the blade. Under the action of centrifugal force, the water flows from the impeller inlet to the outlet. In this process, the kinetic energy and force of water are improved. After the water discharged by the impeller by the spiral diffusion chamber, most of the kinetic energy into pressure energy, and then transported out along the drain. At this time the impeller inlet is due to the discharge of water and the formation of a vacuum. Water in the suction wells under the action of atmospheric pressure, the suction pipe into the impeller. Impeller constantly rotating, drainage will be carried out without interruption.
Mine submersible pump main working parts are impellers, which have a certain number of leaves, impeller fixed on the shaft, driven by the shaft rotation. The pump housing is a spiral diffusion chamber, the suction port of the pump is connected with the water absorption, and the drain is connected with the drain pipe.
Before the pump starts, the water is injected into the pump by the water injection funnel, and then the pump is started. The impeller rotates with the shaft. The water in the impeller is also rotated by the blade. Under the action of centrifugal force, the water flows from the impeller inlet to the outlet. In this process, the kinetic energy and force of water are improved. After the water discharged by the impeller by the spiral diffusion chamber, most of the kinetic energy into pressure energy, and then transported out along the drain. At this time the impeller inlet is due to the discharge of water and the formation of a vacuum. Water in the suction wells under the action of atmospheric pressure, the suction pipe into the impeller. Impeller constantly rotating, drainage will be carried out without interruption.