2016年11月3日星期四

Characteristics and Application Environment and Condition of Stainless Steel Submersible Pump

Stainless steel submersible pump Features:
1, motor, pump – body, diving into the water running, safe and reliable.
2, no special requirements on the well, as long as the water pipe can withstand the corresponding pressure can be.
3, easy installation and maintenance Simple, small footprint, no need to build the pump house.
4, simple structure, saving raw materials.
5, the maximum flow rate up to 1,000 tons per hour, head can reach 1,500 meters.
Stainless steel submersible pump use of the environment and conditions:
1, the power frequency is 50Hz, the rated voltage of 380v or 660v (tolerance + -5%) of the three-phase AC power supply.
2, solid content (by mass) is not greater than 0.01%.
3, the liquid was pumped acid PH value of 1-14.
4, the transmission medium temperature does not exceed 120 ℃.
5, the pump inlet must be below the moving water level lm, but the dive depth does not exceed the static water level to 70m, bottom of the pump from the bottom of the water depth of at least lm.
6, requires well integrity, smooth wall, the well may not stagger, if the pool, you need to add a radiator (shroud).

Reason and method of no water in deep well pump

Well pump out of the water is too little or inadequate for what reasons? And treatment methods
1, the water is too low
Treatment is based on the depth of the flow of water and pump water requirements, the emergence of the deep-well pump with another series of more pumps, and the appropriate increase in the pump tube and drive shaft.
2, the pump section in the gap is too large
Treatment is to adjust the impeller axial clearance.
3, impeller damage
Treatment is to pump out the pump section to replace the impeller.
Deep-well pump motor is running, the pump is not the reasons for what the water? And treatment methods
1, the water is too low, the pump can not absorb water
Treatment is to increase a pump tube and drive shaft.
2, water network blocking
The treatment is to remove the deep well pump from the well, clear the water network plugging and re-install.
3, the pump section into the deep wells too
The treatment method is to increase the pump section one to two pump tube.
What are the reasons for the lack of deep-well pump head? And treatment methods
1, the pump section in the gap is too large
Treatment is to pump out the pump section, adjust the impeller axial clearance.
2, impeller damage
Treatment is to pump out the pump section, replace the impeller.

Maintenance tips for submerged pumps

Pumps that take too long to use, or because of improper handling at some point in time, may require a little trick in the face of liquid pump problems.
1, the maintenance of liquid pump, the first pump removed from the tank, remove the motor and base, remove the lower casing, under the axle and impeller destroyed (note the pump shaft coating) release the bearing Sit six hex bolts, and then put the pump shaft and bearing components can be pulled out together for maintenance.
2, the liquid pump repair and replacement of wearing parts after reassembly, see the bearing, bearing installed in the pump shaft with the upper and lower bearing cover fitted couplings and tight round nut, the correction of the pump shaft Bending, with the bearing pump down into the pump body, and then bearing housings installed in the middle seat, adjust the impeller and upper and lower pump casing clearance just put the impeller and the lower sleeve and the impeller and cap together with the phenolic clay stick Pump shaft, such as phenol-formaldehyde mud completely cured, it will be installed under the pump cover, the assembly is completed, the hand shaft on the shaft rotation about whether the normal. Such as the replacement of bearings and pump shaft, the first axle to remove the pump shaft nut and coupling, loosen the upper and lower bearing cover 12 screws, the bearing can play up to play.

Precautions for submersible pumps when disassembling

Check the submersible pump bearings: Check the motor part of the upper and lower bearings, if found to wear or clearance is too large, must be promptly replaced with new bearings, is strictly improper use.
Check as follows:
If the motor is running, the submersible pump produces a “click” sound, and the cycle and the speed is proportional to, and hand rotation of the rotor is laborious, is the bearing raceway a bit astringent or avulsion phenomenon; if the bearing issued intermittent ” Choking choking “sound, hand rotation of the rotor has an uncertain dead point, usually the submersible pump ball rack damage, rupture of the inner ring or ball broken. In such cases, you must replace the bearings, so as to avoid greater damage.
Submersible pumps in the demolition of the front and rear end cover should be marked with the base of the joints. In the demolition of submersible pumps impeller and bushings and other components, it should be noted that, do not hard punch hard, can be used thermal expansion principle, the edge of the heating side of the Tap or use “Rama” and other tools to remove.
Winding burnout should analyze the reasons, such as overload, card pump, lack of phase, leakage leakage short circuit, etc., in the demolition of submersible pump motor windings, do not make silicon steel tilt shift and glitching phenomena, so as not to assemble the new winding knock ” Bell “caused when the ground or short-circuit fault. Rewinding the new coil, the enameled wire and insulating paper must be selected regular manufacturers, because the submersible pump motor heat resistance level is generally E, B-class. Be sure to pay attention to its heat level corresponding. Insulation should be low enough in thickness and be padded in place. Winding off the assembly line, careful not to make the coil wipe the stator core, but also avoid using the crossed line repeatedly.

2016年11月1日星期二

Submersible pump of the production quality is how to affect its performance

Submersible pump production quality influence on the performance of the submersible pump is great, why do you say that? Because such as when a product prototype test, the hydraulic properties are reaching or higher than the national standard regulation, after putting into production, its performance is not stable, high low, some even fall below products. So the production quality submersible pump is how to affect the performance of it?
Submersible pump production quality affect the performance of pump performance of the submersible pump is composed of the main performance parameters of the flow and head submersible pump and efficiency to characterization. The casting quality of submersible pump flow, head, efficiency, the influence of the spare parts such as impeller and guide shell casting quality is a basic factors influencing the performances of submersible pump, and submersible pump of blank production, machining, assembly, and many other factors.

How can the water pump mechanical seal design

Mechanical seal is an important parts, water pump is a submersible pump leakage prevention, energy saving as well as the important basis of controlling pollution of the environment, design the water pump mechanical seal or there are a number of requirements.
1. The first design the main is to consider the mechanical seal mechanical seal of the working environment.
2. The nature of the medium to be sealed: gas medium; Low boiling point, low saturated vapor pressure of liquid medium; Sealing medium corrosive, solubility; Sealing medium containing impurities, particles; Sealing medium viscosity; Sealing medium of toxic, flammable and explosive;
3. The temperature of the sealed medium, namely the sealed cavity actual temperature: high temperature, normal temperature, low temperature, temperature cross range;
4. The medium pressure, namely the actual pressure seal cavity

Submersible pump stator winding fault inspection method

Submersible pump stator winding fault inspection method is: dry and oil filled type submersible electric pump stator winding short circuit occurs, due to the large short-circuit current, short circuit in overheating, easy insulation aging, coke, crisp, therefore, can use visual inspection of the stator winding insulation scorch place, coke taste and smell check, usually is usually a short circuit in stator winding.
Conditional, simple instrument are available for inspection: in series with the stator winding for three current meter, and then into the low voltage, if the three-phase current meter reading large difference (normal, three-phase current meter readings are not more than 10%. If a difference of more than 10%, showed abnormal situation), the current reading is most likely a phase short circuit phase. Because submersible pump stator winding short circuit is equivalent to a part of the coil in parallel, the phase of the stator winding dc resistance is reduced, the current will become bigger. If use a bridge to check, than the current meter check convenient: as long as the use of bridge submersible pumps in each phase of the stator winding dc resistance, such as the three-phase stator winding resistance differs in more than 5%, the resistance of stator winding is most likely a phase short circuit of a photograph. If there are any short circuit detector, can directly measure the part of the stator winding short-circuit: first the short circuit detector and an ammeter in series connected to the power supply, and then put short circuit detector in submersible pump stator inner circle on the surface of the stator slot, one slot.
If the check to a trough of submersible pump ammeter reading increases suddenly, suggests that the groove of the coil short circuit occurred.