2017年2月14日星期二

The Law of Valve Movement of Fountain Pump

In the experiment, it was found that the movement law of the valve of the fountain pump was not exactly the same as that of the people, and its movement was accompanied by two kinds of rotary motion in addition to the linear motion in the vertical direction. When the plunger movement speed is small, the valve ball around the vertical axis of the horizontal rotation and along the hole in the seat hole that is the valve seat hole axis revolution. The angular velocity of the plunger is related to the velocity of the plunger. The greater the speed of the plunger, the greater the angular velocity of the ball. The special form of the ball is mainly related to the particularity of the valve ball, the seat structure and the impact of the fluid. Deep well pump is a spherical valve, when the fluid around it flows, in the back of the surface layer will be off the phenomenon, while generating a lateral excitation force. Due to the symmetry of the ball, this lateral force will move along the circumference of the "equator" around the ball, so that the ball is not always on the axis of the valve seat, but away from a distance and close to the seat Corner on the rotation, which is the "revolution" phenomenon.
In addition, due to the instability of the fluid flow and the deviation of the ball caused by the fluid relative to the valve ball flow asymmetry, the ball will produce a certain degree of deflection, so that the lateral force is not acting on the core, but in the horizontal There is a certain eccentric, so that the ball in the horizontal plane there is a rotation, that is, "rotation" phenomenon. The above conclusion is obtained in the case of pure liquid. In the gas-liquid mixed-phase flow, due to the existence of bubbles, the flow field disturbance is more intense, and the bubble on the ball has a certain impact, this time the ball movement is more complex, in addition to rotating movement, there are drifting up and down.

Fountain pump use precautions

Fountain pump is actually a well submersible pump, is designed for agricultural irrigation and drainage, sprinkler irrigation, industrial and civil construction of the drainage system developed for ponds, fish ponds, water towers, deep wells and high water delivery.
When using the fountain submersible pump, there are a few points that require special attention:
1, equipment grounding:
In order to ensure the safety of the fountain when used, the state of the mandatory requirements of the submersible pump is to take protective grounding, or once the pump shell leakage, water pump near the water and the reservoir surface will be charged, seriously endanger the safety of humans and animals , Will also cause the waste of electricity.
If the fountain pump metal shell and meet the national standard grounding (grounding resistance is not greater than 4Ω) ground connection, leakage, the current through the pump shell, ground, grounding, ground, transformer working ground wire and power to form a closed Circuit, once the leakage current is too large, is to make the pump protection device work - fuse blow or air switch trip, automatically disconnect the fountain pump power.
2, install the leakage protector:
Once the leakage crisis occurs, as long as the leakage value exceeds the operating current value of the leakage protector, usually not more than 30mA, the leakage protector will work, disconnect the switch, so that the fountain to stop running.
3, the power supply voltage is abnormal when the boot:
As a submersible pump, the voltage is too high, too low will make the pump temperature rise, shorten the life of the pump, or even burn, and now in many places there is a long-term low-voltage power supply line or line terminal voltage is too high, the terminal voltage is too low The problem. Therefore, when the fountain is running, the operator should always pay attention to the power supply voltage value, when the power supply voltage is higher than the rated voltage of 10% or less than the rated voltage of 10%, and the current exceeds the rated current of 20%, should immediately stop, to avoid abnormal voltage Boot.
4, the motor in the opposite direction of rotation:
Although some fountain submersible pumps can reverse the double water, but because of the reverse flow of small current, so reverse the time is too long will damage the motor.
5, to avoid long-term overload work

Mine submersible pump which is good

Mine submersible pump is mainly used for coal mine central pumping station drainage, coal mine flood disaster after the rescue or drainage drainage, commonly used is a centrifugal pump. Mine submersible pumps are commonly used D-type, DA-type and TSW-type multi-stage centrifugal pump; and the bottom of the water and mining area drainage is commonly used B, BA and BZ single-stage centrifugal pump.
    Mine submersible pump main working parts are impellers, which have a certain number of leaves, impeller fixed on the shaft, driven by the shaft rotation. The pump housing is a spiral diffusion chamber, the suction port of the pump is connected with the water absorption, and the drain is connected with the drain pipe.
    Before the pump starts, the water is injected into the pump by the water injection funnel, and then the pump is started. The impeller rotates with the shaft. The water in the impeller is also rotated by the blade. Under the action of centrifugal force, the water flows from the impeller inlet to the outlet. In this process, the kinetic energy and force of water are improved. After the water discharged by the impeller by the spiral diffusion chamber, most of the kinetic energy into pressure energy, and then transported out along the drain. At this time the impeller inlet is due to the discharge of water and the formation of a vacuum. Water in the suction wells under the action of atmospheric pressure, the suction pipe into the impeller. Impeller constantly rotating, drainage will be carried out without interruption.

The axial flow pump controls the inhalation and discharge of the gas

Axial flow pump is a kind of vacuum pump which can keep the gas in and out, so as to achieve the purpose of pumping. There are basically two types of pumps: variable capacity vacuum pump and momentum pump. Variable capacity vacuum pump is divided into reciprocating vacuum pump and rotary vacuum pump, ⑴ reciprocating vacuum pump: the pump is to use the piston to do reciprocating motion, the gas inhalation, compression and discharge. Therefore, also known as piston-type vacuum pump. 250ZLB Axial flow pump Rotary vacuum pump: is the use of pump cavity piston to do the rotary motion, the gas inhalation, compression and discharge. The momentum transfer pump relies on high-speed rotating blades or high-speed jets that transmit momentum to the gas or gas molecules so that the gas is continuously transported from the pump inlet to the outlet. Specific can be divided into the following types. Molecular vacuum pump: it is the use of high-speed rotating rotor to the energy transmission to the gas molecules, so that compression, exhaust a vacuum pump.
    Axial flow pump energy growth, can be satisfied with the urgent need for emergency drainage. The axial flow of the pump is small and the flow is large, and it is used in the power plant for the use of the recirculation pump. But the axial flow pump placement and training things than the horizontal centrifugal pump complex. Slurry pump is small and light, easy to take care, you can pump mud, mortar, deserved in the deserted environment of sewage pumping. The pump is subject to a skill economic objective that weighs the effectiveness of the pump. It refers to the pump's useful power (ie, pump input power) and pump shaft power (ie, pump output power) ratio.

Application of intelligent control and protection of hot water submersible pump

With the rapid development of variable frequency drive technology, computer technology and information technology, the traditional hot water submersible pump manufacturing industry has been toward energy saving, intelligent direction.
  QJR hot water submersible pump intelligent control and protection is a certain emblem processing capacity, in the well with hot water submersible pump application, control and protection can partially replace the function of artificial potassium, the equipment has been planted from the pump factory Intelligent control and protection of the intelligent control technology (software) hardware and integration, the hardware generally include the inverter (cabinet), PLC and pump protection unit. Intelligent control and protection for the safe and reliable operation of the pump and energy conservation has a very significant role.
  Wells with hot water submersible pump operating point is the pump performance curve and the system curve (also known as the pipeline or container to be sexual curve) intersection. The operating efficiency of the pump at the operating point fluctuates violently due to the different operating points. , The operating efficiency of a hot water submersible pump can vary by 40% depending on the operating point.The difference is the potential of the pump system to save energy and improve its reliability.
  The performance curve of the traditional hot water submersible pump is the trajectory of the pump, such as the most commonly used flow-lift curve, NPSHr, and so on. First-class curve and so on.
  In the variable frequency (frequency), the hot water submersible pump performance curve with the pump speed changes in accordance with similar laws of movement, the trajectory of the formation of multiple performance fan. Each sector can be composed of a performance curve when connecting the maximum speed and a performance curve set at minimum speed, such as flow-lift fan, NPSHr flow, and so on.
  Performance of hot water submersible pump fan performance curve than the pump has a greater intersection with the system curve and more control selectivity. The variability of this interaction leads to large fluctuations in the efficiency and reliability of the pump, which is necessary for intelligent control and protection of the pump. If the pump control and protection to adapt to this change, the pump operation efficiency is high and smooth and maintenance is low. On the contrary, if the pump control and protection can not adapt to this diversity, the wells with hot water submersible pump operating efficiency is low, uneven and maintenance and high.

Hot water submersible pump instrument selection and control protection requirements

Hot water submersible pumps are widely used in various types of geothermal wells, hot springs and high temperature hot water lifting devices. The purpose of the control system is to monitor the operation status of the hot water submersible pump group, Whether the ancillary system is working properly, early detection of hot water submersible pump components failure, make predictive maintenance plans to reduce unplanned downtime, to avoid catastrophic accidents. Monitoring instrumentation, control and protection system settings generally meet:
(1), different types of geothermal wells, hot spring wells and high temperature hot water lifting device process operation requirements and protection of technological equipment (or other equipment within the device) requirements;
(2), the requirements of safe and efficient operation of hot water submersible pumps and the requirements of operation status monitoring;
(3), ancillary systems, such as lubricating oil stations, control and protection requirements
(4), drive system control protection requirements.
  Hot water submersible pump monitoring can be divided into online real-time monitoring [hot water submersible pump intelligent control] and off-line periodic monitoring of two categories, for small, general use, or less important in the device pump can be considered cyclical Monitoring (eg using a portable monitor). For the high investment of large pumps, you can consider setting up a more complete online monitoring system.
1), on-line monitoring instrumentation, control and protection system settings to consider the use of hot water submersible pumps, geothermal wells, hot springs and high temperature hot water lifting device in the importance of (pump caused by the loss of production), pump Failure probability, failure mode, the second hazard caused by the accident, the cost and time of the maintenance, the operating conditions, the operation mode, the operation experience and so on.
  As a general principle, the following two factors can be considered:
    ① the principle of reliability. Reliability of the first principle is: simple is reliable; so in the configuration monitoring, control and protection system, to avoid the configuration too much, not too much of the necessary instruments, if too much is not necessary to set the instrument and control, Not only can not increase the reliability of the pump group but also become the source of the accident.
    ② economic principles. The configuration of the monitoring, control and protection system takes into account the economy, such as an investment and subsequent maintenance costs. At the same time, the monitoring, control and protection of the pump should also take into account the environmental protection needs, such as the impact of leakage of the hot water submersible pump seal on the environment.
2), according to QJR hot water submersible pump type, structural characteristics, component failure mode, to determine the physical parameters to be monitored. Commonly used monitoring parameters are power monitoring, temperature monitoring (such as bearing temperature, oil temperature, shell temperature, motor stator winding temperature), corrosion monitoring, leak monitoring (such as QJR well with hot water submersible pump inlet and outlet valve leakage, mechanical seal Leakage monitoring), pressure monitoring (inlet and outlet pressure), speed monitoring, phase monitoring, well hot water submersible pump flow monitoring, bearing vibration monitoring, shaft vibration monitoring, shaft displacement monitoring, axial thrust monitoring, torque monitoring, no sealing heat Water submersible pump bearing wear monitoring, lubricating oil analysis.
3) Select the monitoring method, monitor the instrument and the installation location according to the physical parameters of the monitoring. By monitoring, recording and analyzing the physical parameters of certain parts of the hot water submersible pump, the operation status of the hot water pump is judged, controlled and protected, and the QJR hot water submersible pump maintenance plan is made according to the change trend of the recorded monitoring data

Optimum Design of Anti - abrasion Metal Material for Axial Flow Pump

Optimum Design of Anti - abrasion Metal Material for Axial Flow Pump
Axial flow pump working in muddy water are severely damaged and severely damaged, requiring frequent downtime and even forced flooding during flooding, resulting in significant economic and energy losses. Therefore, to solve the problem of rapid wear and tear damage of axial pump is an important task of hydropower development. Abrasion is the result of combined action of cavitation and sediment erosion wear [1]. According to the site observation, abrasion damage is much more serious than individual cavitation or separate sediment wear. Because of the current mechanism of metal erosion damage has not been fully understood [2], coupled with the study of anti-abrasion of metal materials and the lack of comprehensive and systematic reports, anti-abrasive materials research is still more use of test and empirical methods for time-consuming trial exploration. In order to make anti-abrasive material development, design and application of detours, we must grasp the law and system of anti-abrasive material design. This paper discusses the research results in anti - abrasive materials, and reveals the inherent laws and systems of anti - abrasion material design. 1 Test materials and methods In the basic research of anti-abrasive material design, 10 kinds of industrial pure metals such as aluminum, magnesium, zinc, copper, iron, nickel, molybdenum, chromium, cobalt and tungsten were used as test materials. 30mm × 6mm test piece, in the electromagnetic resonance high-speed bubble generator with industrial water as a medium to accept cavitation test to thin film per unit time as a basis for measurement of cavitation loss.