Hot Rolling Process of Mixed Flow Pump Impeller
At present, there are three kinds of processing methods of mixed flow pump impellers at home and abroad: (1) sand casting and grinding processing; (2) sand casting CNC machining; (3) molding hot bending (1/2 CNC machining). The first method is simple, but the labor intensity of workers, foreign has been rarely used, and domestic also as the main method of processing leaves. The second method of processing out of the leaves of high precision, but the cycle is long, there is not enough domestic five-axis milling bed to meet the requirements of the production schedule. The third method to obtain the blade surface and internal performance are good, but also to meet the general product production requirements. However, the pressure technology has been limited to the curvature of the change is not limited, the thickness of the more uniform leaves, for the sculpture body surface of the Francis turbine runner blade pressure technology remains to be further studied. Three Gorges unit mixed flow pump single output 7lOMW, wheel diameter IOm, a single leaf weight 18t. Our company to small Danjiang power station turbine rotor blades as the middle of the leaves, made a series of hot pressing process attempts, including hot pressing hot pressing mold design and manufacturing is a crucial link
2017年2月14日星期二
Study on Temperature Rise Mechanism of Axial Flow Pump
Study on Temperature Rise Mechanism of Axial Flow Pump
To reduce complications, mechanical cardiac assist devices are becoming smaller. As the clinical application in recent years proved that continuous non-Bo blood flow can be adapted to the body, the use of high-speed rotation of the impeller to drive the blood can also reduce the volume of the pump, so the electric axial flow of the heart of the auxiliary pump has become a hot topic in this field. The author of the Chinese Academy of Medical Sciences Fu Wai Cardiovascular Hospital on the heart of a long-term systematic study. Recently developed axial pump has reached short-term clinical application requirements. In order to achieve long-term application goals, we put forward the idea of "miniature axial flow pump in the apical chamber wall" based on the previous research experience, and carried out the prototype development. In the development process found that with the miniaturization of the axial flow pump, the speed gradually increased, some characteristics of the pump motor deterioration, efficiency. This trend increases the temperature of the pump in the working state. Excessive pump surface temperature can cause similar damage to the organization, resulting in exudative inflammatory response, reduce the physiological compatibility. We developed the "apical chamber wall micro-axial pump", intended to be implanted into the apex muscle wall, due to the miniaturization of the pump is very high, poor heat dissipation conditions, temperature control has become an important part of the study. Such studies have not been reported in domestic and foreign literature. In this paper, the factors influencing the temperature rise of the blood pump were discussed through the comparative analysis of the micro-axial pump in the apical chamber wall, which laid the foundation for the proposed control scheme.
To reduce complications, mechanical cardiac assist devices are becoming smaller. As the clinical application in recent years proved that continuous non-Bo blood flow can be adapted to the body, the use of high-speed rotation of the impeller to drive the blood can also reduce the volume of the pump, so the electric axial flow of the heart of the auxiliary pump has become a hot topic in this field. The author of the Chinese Academy of Medical Sciences Fu Wai Cardiovascular Hospital on the heart of a long-term systematic study. Recently developed axial pump has reached short-term clinical application requirements. In order to achieve long-term application goals, we put forward the idea of "miniature axial flow pump in the apical chamber wall" based on the previous research experience, and carried out the prototype development. In the development process found that with the miniaturization of the axial flow pump, the speed gradually increased, some characteristics of the pump motor deterioration, efficiency. This trend increases the temperature of the pump in the working state. Excessive pump surface temperature can cause similar damage to the organization, resulting in exudative inflammatory response, reduce the physiological compatibility. We developed the "apical chamber wall micro-axial pump", intended to be implanted into the apex muscle wall, due to the miniaturization of the pump is very high, poor heat dissipation conditions, temperature control has become an important part of the study. Such studies have not been reported in domestic and foreign literature. In this paper, the factors influencing the temperature rise of the blood pump were discussed through the comparative analysis of the micro-axial pump in the apical chamber wall, which laid the foundation for the proposed control scheme.
Cavitation characteristics of mixed flow pump
Characteristics of cavitation and cavitation performance of mixed - flow pump
As a hydrodynamic propulsion unit, a mixed flow pump is required to meet specific flow, lift and cavitation performance requirements at the moment of start-up, and the size and quality are severely limited [1] and [2]. In general, stable working conditions, the pump cavitation characteristics have been more research [3 ~ 8]. In this paper, according to the special requirements of high-speed mixed-flow pump, the characteristics of cavitation erosion during start-up are analyzed according to the special properties of the parameters such as speed and flow rate. And the main measures to improve the cavitation performance of high-speed mixed-flow pump are proposed. In the process of start-up, the performance parameters such as speed, flow and head of the mixed-flow pump and the inlet conditions change rapidly with time, and the generation and development of cavitation is also very complex. In the process of starting the cavitation phenomenon, the use of 1200r / min speed of the model pump for cavitation and no cavitation conditions under the start-up test
As a hydrodynamic propulsion unit, a mixed flow pump is required to meet specific flow, lift and cavitation performance requirements at the moment of start-up, and the size and quality are severely limited [1] and [2]. In general, stable working conditions, the pump cavitation characteristics have been more research [3 ~ 8]. In this paper, according to the special requirements of high-speed mixed-flow pump, the characteristics of cavitation erosion during start-up are analyzed according to the special properties of the parameters such as speed and flow rate. And the main measures to improve the cavitation performance of high-speed mixed-flow pump are proposed. In the process of start-up, the performance parameters such as speed, flow and head of the mixed-flow pump and the inlet conditions change rapidly with time, and the generation and development of cavitation is also very complex. In the process of starting the cavitation phenomenon, the use of 1200r / min speed of the model pump for cavitation and no cavitation conditions under the start-up test
2017年2月13日星期一
Characteristics of Fountain Submersible Pump
Fountain submersible pump its shell, flow parts and external parts are made of cast iron or stainless steel (304,316,316 L) made, and the product also retains the original fountain pump performance.
1, the use of cast iron or stainless steel, pump to improve the corrosion resistance.
2, impeller with special materials to prevent the impeller when the impeller loose.
3, leakage protection measures: the use of fixed potential grounding device.
4, on the basis of the original ordinary pump, according to the requirements of the fountain dedicated pump, the company after several tests, in the technical development, continuous improvement of processing materials, fountain dedicated pump can be frequent start, completely suitable for the use of music fountain.
5, the pump with stainless steel filter cover, three-phase four-wire cable.
6, stainless steel fountain pump for automatic water injection function.
7, the motor is self-circulating water-cooled.
1, the use of cast iron or stainless steel, pump to improve the corrosion resistance.
2, impeller with special materials to prevent the impeller when the impeller loose.
3, leakage protection measures: the use of fixed potential grounding device.
4, on the basis of the original ordinary pump, according to the requirements of the fountain dedicated pump, the company after several tests, in the technical development, continuous improvement of processing materials, fountain dedicated pump can be frequent start, completely suitable for the use of music fountain.
5, the pump with stainless steel filter cover, three-phase four-wire cable.
6, stainless steel fountain pump for automatic water injection function.
7, the motor is self-circulating water-cooled.
Fountain submersible pump service life
Fountain submersible pump industry standard warranty period of one year, but even the same manufacturer of the same type of water pump, because the use of the environment, operating standards, the different materials, the life gap is huge. In addition to the selection of fault, transportation, misuse and extremely harsh operating conditions and other special reasons outside the normal circumstances, in addition to wearing parts, fountain submersible pumps to use two or three years is not a big problem. Many may also be used for five to eight years.
From the transport of materials to analyze: If you contain a lot of hard dirt, fountain submersible pump over-current material will speed up wear and tear, but in the transmission of similar lubricating substances, will play a role in extending life, so the industry did not Fountain submersible pump life to a standard material under the test method and basis, but directly through the quality of the package to explain.
From the standard operation and adhere to the regular maintenance aspects, this is even more obvious. In order to better ensure that the fountain submersible pump is stable and efficient long-term use, for all customers given the following meaning:
1, should find out the direction of rotation of the motor, there are many types of fountain submersible pump is forward and reverse when the water can be, but the reversal of small water, the current is large, the reversal of a long time will damage the motor windings.
2, as a result of low-voltage power supply line is relatively long, the end of the line voltage is too low is common. When the phase voltage is less than 198 volts, the line voltage is lower than 342 volts, the fountain submersible pump motor speed down, when less than 70% of the rated speed, start the centrifugal switch will be closed, resulting in long start winding power and heat or even burn Bad windings and capacitors. Conversely, a high voltage causes the motor to overheat and burn out the winding. Therefore, the fountain submersible pump in operation, the operator must always observe the power supply voltage value, if less than 10% of the rated voltage, higher than 10% of rated voltage above, the motor should stop running, find out the cause and troubleshooting.
3, install the fountain submersible pump, the cable to overhead, the power cord not too long. Fountain submersible pump into the water or put forward not to force the cable to avoid breaking the power cord. Fountain submersible pump work do not sink into the mud, otherwise it will lead to poor heat dissipation and electrical motor winding. Installation, the motor insulation resistance should not be less than 0.5 megohm.
4, leakage protection device, also known as security device, its role from the "security device" the three words can be understood. Because the fountain submersible pump in the water, easy to leakage caused by power loss and even lead to electric shock accident. If equipped with leakage protection device, as long as the leakage of fountain submersible pump leakage current value exceeds the leakage protection device (generally not more than 30 mA), leakage protection device will cut off the fountain submersible pump power to ensure safety, while avoiding leakage, waste Electricity.
5, do not frequently switch fountain submersible pump, this is because the pump stall will produce a return flow, if immediately start, will make the motor load start, resulting in starting current is too large and burn out the winding. As the start current is very large, frequent start will burn the fountain submersible pump motor windings.
6, in order to avoid the fountain submersible pump long-term overload, do not smoke a large amount of sediment water and observe whether the current value specified in the nameplate value, if the current is too large, should stop inspection. In addition, the dehydration pump running time should not be too long, so as not to make the motor overheating and burned.
7, usually should always check the motor, if found under the cover of a crack, rubber seal ring damage or failure, should be replaced or repaired, to avoid water infiltration fountain submersible pump. The use of fountain submersible pump protection and pay attention to some of the daily protection can better extend the fountain submersible pump life.
QSP fountain pump installation
Fountain submersible pump installation
The fountain submersible pump is one of the main components in the fountain system, providing power to the fountain. Fountain pump installation is also relatively simple, mainly based on the installation of space to choose the installation, installation of the fountain is divided into horizontal installation and vertical installation of two, the following brief look at two ways and means of the way.
1, horizontal installation
Horizontal installation is to let the pump level lie down, making the pump shaft and pipeline in the same plane, and in the same horizontal plane. Horizontal installation fountain pool depth can not be deep, just to be able to submerged the pump can be, but the fountain pump to occupy a sufficient area of the plane. Fountain submersible pump cooling need to rely on external water cooling, so the fountain pump from the bottom of the pool shall not be less than 100mm, the pump with the bracket fixed.
2, vertical installation
Pump shaft and trunk center line to be vertical, so you can reduce the size of the fountain pool, theoretically need to deepen the fountain to pump the height, but the actual construction of the fountain area is more localized. In order to repair the fountain pump, easy to replace. Sufficient spacing should be maintained between the pump outlet flange and the piping.
Fountain pump installation must choose the right way, this will reduce the cost of civil construction and management expenses, and pump operation and maintenance will be very convenient, the appropriate installation so that the overall appearance of the fountain system looks beautiful.
QSP fountain pump is mainly used for fountain landscape, rockery landscape, aquaculture and other places. Widely used in low-lift cities, farmland irrigation, sprinkler irrigation; industrial and civilian supply and drainage systems, hills, mountain water, and low-lying land to exclude water.
The fountain submersible pump is one of the main components in the fountain system, providing power to the fountain. Fountain pump installation is also relatively simple, mainly based on the installation of space to choose the installation, installation of the fountain is divided into horizontal installation and vertical installation of two, the following brief look at two ways and means of the way.
1, horizontal installation
Horizontal installation is to let the pump level lie down, making the pump shaft and pipeline in the same plane, and in the same horizontal plane. Horizontal installation fountain pool depth can not be deep, just to be able to submerged the pump can be, but the fountain pump to occupy a sufficient area of the plane. Fountain submersible pump cooling need to rely on external water cooling, so the fountain pump from the bottom of the pool shall not be less than 100mm, the pump with the bracket fixed.
2, vertical installation
Pump shaft and trunk center line to be vertical, so you can reduce the size of the fountain pool, theoretically need to deepen the fountain to pump the height, but the actual construction of the fountain area is more localized. In order to repair the fountain pump, easy to replace. Sufficient spacing should be maintained between the pump outlet flange and the piping.
Fountain pump installation must choose the right way, this will reduce the cost of civil construction and management expenses, and pump operation and maintenance will be very convenient, the appropriate installation so that the overall appearance of the fountain system looks beautiful.
QSP fountain pump is mainly used for fountain landscape, rockery landscape, aquaculture and other places. Widely used in low-lift cities, farmland irrigation, sprinkler irrigation; industrial and civilian supply and drainage systems, hills, mountain water, and low-lying land to exclude water.
Hot water submersible pump motor performance _ Features
Hot water submersible pump motor mainly submersible submersible motor; set built-in lightning protection, * thermal protector, * using electronic starter.
① no centrifugal switch, no capacitance, to avoid mechanical loss, increase the number of starts, reduce the volume.
② stator outside the mountain stainless steel welding, there are stainless steel lining, sealed by the epoxy resin filling. Sealing performance, corrosion resistance, heat fast, anti-deep water pressure, long life, reduce costs.
③ closed squirrel cage rotor, slot using high-quality copper, before and after the copper end ring welded, not easily deformed or broken, good electrical conductivity, high efficiency. Steel is not rotted by chemical treatment.
④ use of thrust bearings, can carry a greater axial load, said by the awkward said the stone to attack the general category of maintenance.
⑤ motor from the water lubrication, internal and external water cooling, the use of water to avoid pollution. The normal working dive depth of up to 900 meters, to solve the domestic deep water operations and scientific research problems.
* Refers to single-phase two-wire motor installed.
For proper installation, please read the instruction manual carefully before use. The power supply and fittings must be installed in accordance with local and international codes, and all metal fittings and hot water submersible pumps should be grounded. All ground lines shall not be less than the specifications of the motor cables. External power cord to be greater than the motor, seven source leads, then the product must be absolutely sealed. Be sure to use within the rated voltage range, if the voltage is ultra-high ultra-low, hot water submersible pump motor will not work. In order to reduce the risk of electric shock, can not be used or water to connect the power cord, do not use the swimming area in the submersible pump.
① no centrifugal switch, no capacitance, to avoid mechanical loss, increase the number of starts, reduce the volume.
② stator outside the mountain stainless steel welding, there are stainless steel lining, sealed by the epoxy resin filling. Sealing performance, corrosion resistance, heat fast, anti-deep water pressure, long life, reduce costs.
③ closed squirrel cage rotor, slot using high-quality copper, before and after the copper end ring welded, not easily deformed or broken, good electrical conductivity, high efficiency. Steel is not rotted by chemical treatment.
④ use of thrust bearings, can carry a greater axial load, said by the awkward said the stone to attack the general category of maintenance.
⑤ motor from the water lubrication, internal and external water cooling, the use of water to avoid pollution. The normal working dive depth of up to 900 meters, to solve the domestic deep water operations and scientific research problems.
* Refers to single-phase two-wire motor installed.
For proper installation, please read the instruction manual carefully before use. The power supply and fittings must be installed in accordance with local and international codes, and all metal fittings and hot water submersible pumps should be grounded. All ground lines shall not be less than the specifications of the motor cables. External power cord to be greater than the motor, seven source leads, then the product must be absolutely sealed. Be sure to use within the rated voltage range, if the voltage is ultra-high ultra-low, hot water submersible pump motor will not work. In order to reduce the risk of electric shock, can not be used or water to connect the power cord, do not use the swimming area in the submersible pump.