Type of Transformer Electricity Control for Mine Submersible Pump Transformer
Low-pressure mine drainage pump starts, the need to go through the transformer 6kV or 3kV high voltage into low-voltage motor to adapt to the rated voltage, usually 660V or 380V. Mining transformers are divided into mine type and mining type explosion-proof type. Mine general type has KSJ series, KSJL series, only applicable to mine underground no explosion dangerous place; mine explosion-proof type has KSGB type and so on, adapted to have the explosion danger place.
KSJ-type power transformers are mine-type electrical equipment in general, on both sides of the tank with high and low voltage cable junction box. In order to avoid the oil pillow and the tank connection pipe plug explosion occurred, the upper oil left oil expansion space, the top cover oil filler plug is equipped with ventilation holes. Transformer oil due to high temperature decomposition of the gas, released from the hole in the plug, remove the plug can be added inward insulating oil.
Transformer high voltage winding with adjustable secondary voltage ± 5% of the tap. When the supply voltage is longer than 95% of the rated voltage, the tap is adjusted to a 5% of the terminals; the other hand, when the power supply voltage is higher than 105% of the rated voltage, the tap adjustment in the +5% To ensure that the low-voltage side of the normal.
In order to meet the two kinds of power supply voltage level, the secondary winding has two kinds of wiring ways (star, triangle connection), 660V for Y wiring, 380V for △ wiring.
Under normal circumstances, the mine drainage pump transformer to ensure that there is a run, a spare. Two transformers can run side by side, but also run separately. Two transformers run side by side to meet the following conditions:
1, the same wiring group.
2, variable ratio difference shall not exceed 0.5%,
3, the short circuit voltage difference shall not exceed 10%,
4, two transformers than the capacity of not more than 3: 1,
Insulation aging caused by the main transformer is the temperature rise, the general oil-immersed transformer using A-class insulation, A-class insulation of the maximum allowable temperature of 105 ℃, the coil allows the temperature rise of 65 ℃. The allowable temperature rise of the transformer oil is 55 ° C.
KSGB-type transformer for the flameproof transformer, the internal oil-filled, shell has a greater intensity. High and low voltage coils are multi-layer cylindrical structure, the transformer is H-class insulation, can work at 165 ℃ long-term operation temperature.
2017年1月19日星期四
The flow field in deep well submersible pump is the key to improve the performance of deep well pump
Studying the flow field in deep well submersible pump is the key to improve the performance of deep well pump.
With the PIV technology, LDV technology and ultrasonic technology matures, people can already use these advanced flow field test technology without disturbing the flow field for high-precision measurement.
In this paper, we use PIV (Particle Image Velocimetry) to study the flow field of deep well pump in Canada. The main content of this paper is to measure the distribution of the flow field in the pump at different flow rates, Similarities and Differences of Flow Field in Deep Well Pumps for Single - phase and Miscible.
Test procedure:
The industrial white oil with density and viscosity similar to that of crude oil was used as the test medium, and GDX501 polystyrene pellets with density close to that of white oil were used as tracer particles. A 10-W neon laser generator and its corresponding light path system were used as the illumination source of the PIV camera, and the PIV images were recorded by video or photographic method. For different working conditions, the PIV images of deep well pump cylinder, pump valve, plunger and other parts were recorded and photographed under single-phase and gas-liquid two-phase medium, respectively, in order to prepare for further analysis and processing.
Experimental results and analysis:
Because of the research on the flow field of the deep well pump fixed valve has been the corresponding research results, and gas-liquid two-phase flow PIV image processing program is imperfect, so here focused on the analysis of single-phase fluid flow medium when the deep well pump valve and column Plug the flow field.
Movement law of deep well pump
In the experiment, it is found that the movement law of the deep well pump valve is not exactly the same as it is known to people. Its motion is accompanied by two kinds of rotary motion besides the vertical linear motion. When the piston moving speed is small, the valve ball around the horizontal axis up and down rotation; when the piston movement speed is greater, the ball around the vertical axis of the horizontal rotation and along the valve seat hole hole angle of the central axis of the valve seat orbital revolution. The rotation speed of the piston and the speed of movement of the plunger, the greater the speed of movement of the plunger, the greater the rotation speed of the valve ball. The special form of movement of the ball is mainly related to the particularity of the valve ball, the seat structure and the impact of the fluid. Deep well pump valve is a spherical valve, when the fluid flows around it, in its rear will be the phenomenon of the detachment of the surface layer, while producing a lateral excitation. Due to the symmetry of the ball, this lateral excit- ing force will move around the "equator" of the valve ball so that the ball does not always lie on the axis of the valve seat bore, but rather deviates a distance and abuts against the valve seat Corner rotation, this is the "revolution" phenomenon.
In addition, due to fluid flow instability and the deviation of the valve ball caused by fluid flow relative to the ball valve asymmetry, the ball will have some flexibility, so that the lateral force is not acting on the core, but in the horizontal plane There is a certain degree of eccentricity, so that the ball in the horizontal plane there is a rotation, the "rotation" phenomenon. The above conclusion is obtained in the case of pure liquid. In the gas-liquid mixed-phase flow, due to the presence of bubbles, the flow field disturbance is more intense, and bubbles on the ball has a certain impact, this time the ball movement is more complex, in addition to rotating movement, there are up and down violent beating
2017年1月18日星期三
Deep well submersible pump in operation to pay attention to the six major issues
Deep well submersible pumps on the operation of the six major issues, some friends may also not very clear, let's learn about it.
1) deep well submersible pumps work, pay attention to the situation of water level decline, wells with submersible pumps shall not work out of the water surface.
2) The use of wells with a submersible pump stop, less water, noise and thermal protector frequent take-off and so on, should stop the pump in time.
3) Check the power supply voltage is too low or power, cable breakage or lack of phase.
4) Check whether the impeller jam or wear, whether the water chamber blockage, head too high or too low, the filter is blocked and so on. If a fault, find the appropriate solution.
5) In case of stator winding burnout and other failures, shall be sent to the repair unit repair. Reassembly, the sealing parts to be 0.2MPa pressure check.
6) When the submersible pump is used, it is found that the damaged cable is replaced immediately before it can be used. If there is a period of time, wells with submersible pumps should not be infiltrated into the water, should be cleaned. Such as wells with a submersible pump for pumping more viscous slurry, should be placed in clean water running for a few minutes, wash the pump slurry, and then dry painted anti-rust oil, stored in dry gout.
1) deep well submersible pumps work, pay attention to the situation of water level decline, wells with submersible pumps shall not work out of the water surface.
2) The use of wells with a submersible pump stop, less water, noise and thermal protector frequent take-off and so on, should stop the pump in time.
3) Check the power supply voltage is too low or power, cable breakage or lack of phase.
4) Check whether the impeller jam or wear, whether the water chamber blockage, head too high or too low, the filter is blocked and so on. If a fault, find the appropriate solution.
5) In case of stator winding burnout and other failures, shall be sent to the repair unit repair. Reassembly, the sealing parts to be 0.2MPa pressure check.
6) When the submersible pump is used, it is found that the damaged cable is replaced immediately before it can be used. If there is a period of time, wells with submersible pumps should not be infiltrated into the water, should be cleaned. Such as wells with a submersible pump for pumping more viscous slurry, should be placed in clean water running for a few minutes, wash the pump slurry, and then dry painted anti-rust oil, stored in dry gout.
Cause of overheating of submersible pump motor
Weihu submersible pump manufacturers combined with many years of experience in pump system, professional team for your analysis of submersible pumps supporting the reasons for overheating the motor,
First, the power source of the reasons: the voltage is too high or low, under a specific load, if the voltage range should be in the range of +10% to -5% of the rated value will cause the motor overheating; power three-phase voltage asymmetry, Phase-to-phase voltage interphase imbalance of more than 5%, will lead winding overheating; phase operation, experience shows that more than 85% of agricultural motor is burned due to lack of phase operation caused by motor phase protection device should be installed.
Second, the reasons for submersible pumps: selection of power is not complete, small horse-drawn carts, motor overload operation for a long time, so that the motor temperature is too high; start too frequently, fixed or short-time intermittent work of the motor system for continuous work. Should limit the number of starts, the correct choice of thermal protection, according to the calibration of the motor using the quota.
The stator windings are short-circuit, inter-turn short-circuit or local grounding, light when the local overheating of the motor, in severe cases when the insulation is not connected to the motor, Burnout; squirrel cage rotor broken or defective, the motor running 1 to 2 hours, the core temperature increased rapidly; ventilation system failure, should check whether the fan is damaged, the direction of rotation is correct, whether the ventilation duct blockage; Eccentric cleaning chamber so that the stator and rotor core phase wiping metal impact sound, the rapid increase in core temperature, a serious electric motor smoke, and even coil burned.
Fourth, the working environment reasons: the motor winding damp or dust, oil, etc. attached to the winding, resulting in lower insulation. The insulation resistance of the motor should be measured and cleaned, dried; the ambient temperature is too high. When the ambient temperature exceeds 35 ℃, the inlet air temperature is high, the motor temperature is too high, should try to improve their working environment. Such as scaffolding shade.
Reminded: due to electrical causes of failure, should be requested to obtain professional qualification certificate of electrical maintenance, knowledgeable people can not blindly repair, to prevent the occurrence of personal injury accidents.
First, the power source of the reasons: the voltage is too high or low, under a specific load, if the voltage range should be in the range of +10% to -5% of the rated value will cause the motor overheating; power three-phase voltage asymmetry, Phase-to-phase voltage interphase imbalance of more than 5%, will lead winding overheating; phase operation, experience shows that more than 85% of agricultural motor is burned due to lack of phase operation caused by motor phase protection device should be installed.
Second, the reasons for submersible pumps: selection of power is not complete, small horse-drawn carts, motor overload operation for a long time, so that the motor temperature is too high; start too frequently, fixed or short-time intermittent work of the motor system for continuous work. Should limit the number of starts, the correct choice of thermal protection, according to the calibration of the motor using the quota.
The stator windings are short-circuit, inter-turn short-circuit or local grounding, light when the local overheating of the motor, in severe cases when the insulation is not connected to the motor, Burnout; squirrel cage rotor broken or defective, the motor running 1 to 2 hours, the core temperature increased rapidly; ventilation system failure, should check whether the fan is damaged, the direction of rotation is correct, whether the ventilation duct blockage; Eccentric cleaning chamber so that the stator and rotor core phase wiping metal impact sound, the rapid increase in core temperature, a serious electric motor smoke, and even coil burned.
Fourth, the working environment reasons: the motor winding damp or dust, oil, etc. attached to the winding, resulting in lower insulation. The insulation resistance of the motor should be measured and cleaned, dried; the ambient temperature is too high. When the ambient temperature exceeds 35 ℃, the inlet air temperature is high, the motor temperature is too high, should try to improve their working environment. Such as scaffolding shade.
Reminded: due to electrical causes of failure, should be requested to obtain professional qualification certificate of electrical maintenance, knowledgeable people can not blindly repair, to prevent the occurrence of personal injury accidents.
Assembly Process Analysis of Deep Well Submersible Pump
Deep well submersible pump installation requirements rubber ring surface intact, remove the old circle is not allowed to re-use, the new rubber ring should be 2% to 5% of the amount of stretch, circle body is not allowed to flip, can not fall into the motor interior or Damaged by mouth. Tighten the bolts should be tightened in turn, section compression rate to ensure that 15% to 25% or so to prevent the ring body compression or excessive compression caused by sealing failure. Shaft seal: shaft seal is generally located in the shaft extension side of the motor, the use of rotating shaft lip seal (skeleton oil seal), is a rotary seal, which consists of elastic lip, metal frame, spring three parts. Applicable line speed up to 30m / s. It is mainly to prevent impurities in the water and sand into the submersible pump interior. Attention should be paid to maintain the correct position of the spring assembly to prevent spring force from overflowing.
Thermal protection Built-in thermal protection is a bimetal-type protection element, commonly used in dry submersible pumps. When used in series with the motor windings, the motor can provide thermal overload, phase loss and stall protection, the action life of more than 1000 times. For three-phase submersible pumps, the thermal protector is connected to the winding center of the Y-connected. For single-phase submersible pumps, the thermal protector is connected in series with the primary and secondary windings. Pressure test with double-sided mechanical seal or double-track single-ended mechanical seal dry and oil-filled submersible pump should be assembled after the pressure test, the test pressure is generally generated by the compressed air pump, no conditions can be used high-pressure air cylinder string pressure gauge instead of air pump. The pump-side seal shall be subjected to the test pressure equal to the maximum pump head pressure, but shall not be less than 0.2 MPa. The pressure test shall last for 5 min and the seal shall be free of leakage. The inner cavity of the motor and the seal on the motor side shall be capable of withstanding a pressure test of not less than 0.2 MPa for 5 min without leakage or other anomalies
Thermal protection Built-in thermal protection is a bimetal-type protection element, commonly used in dry submersible pumps. When used in series with the motor windings, the motor can provide thermal overload, phase loss and stall protection, the action life of more than 1000 times. For three-phase submersible pumps, the thermal protector is connected to the winding center of the Y-connected. For single-phase submersible pumps, the thermal protector is connected in series with the primary and secondary windings. Pressure test with double-sided mechanical seal or double-track single-ended mechanical seal dry and oil-filled submersible pump should be assembled after the pressure test, the test pressure is generally generated by the compressed air pump, no conditions can be used high-pressure air cylinder string pressure gauge instead of air pump. The pump-side seal shall be subjected to the test pressure equal to the maximum pump head pressure, but shall not be less than 0.2 MPa. The pressure test shall last for 5 min and the seal shall be free of leakage. The inner cavity of the motor and the seal on the motor side shall be capable of withstanding a pressure test of not less than 0.2 MPa for 5 min without leakage or other anomalies
Structure Description of Multistage Deep Well Submersible Pump
1, multi-stage deep well submersible pump unit by: pumps, submersible motors (including cables), water pipes and control switch four major components.
The submersible pump is a single-suction multi-stage vertical centrifugal pump. The submersible motor is a wet-type, vertical three-phase cage induction motor. The motor and water pump are directly connected by a claw type or single cartridge type coupler. Equipped with different specifications of three Core cable; starting equipment for the different capacity levels of air switch and self-dual decompression starter, the water pipe is made of different diameter steel pipe, flange connection, high-lift pump gate valve control.
2, submersible pumps each stage diversion shell is equipped with a rubber bearing; impeller tapered sleeve fixed to the pump shaft; diversion shell with threaded or bolted together into one.
3, high head submersible pump with a check valve at the top, to avoid downtime caused by water damage to the unit.
4, the upper part of the submersible motor shaft with a labyrinth of sand and two reverse assembly of the oil seal to prevent the flow of sand into the motor.
5, submersible motor with water-lubricated bearings, the lower part with rubber pressure regulating film, pressure regulating spring, composed of surge chamber, regulating the temperature changes caused by the pressure; motor winding with polyethylene insulation, nylon sheath durable consumer goods water magnet wire , Cable connection by QJ-type cable connector technology, the joint insulation off scratch paint layer, were connected, welding firm, with a layer of raw rubber around. And then wrapped with 2 to 3 layers of waterproof adhesive tape, wrapped with 2 to 3 layers of waterproof adhesive tape or a layer of rubber tape wrapped with water (bike belt) to prevent seepage.
6, the motor is closed, the use of precision only bolts, cable exports plus pads for sealing.
7, the motor has a water injection hole at the top, there is a vent, the lower part of a drainage hole.
8, the motor is equipped with the upper and lower thrust bearing on the bottom, thrust bearing groove for cooling, and it is the stainless steel thrust plate, with the pump up and down the axial force.
The submersible pump is a single-suction multi-stage vertical centrifugal pump. The submersible motor is a wet-type, vertical three-phase cage induction motor. The motor and water pump are directly connected by a claw type or single cartridge type coupler. Equipped with different specifications of three Core cable; starting equipment for the different capacity levels of air switch and self-dual decompression starter, the water pipe is made of different diameter steel pipe, flange connection, high-lift pump gate valve control.
2, submersible pumps each stage diversion shell is equipped with a rubber bearing; impeller tapered sleeve fixed to the pump shaft; diversion shell with threaded or bolted together into one.
3, high head submersible pump with a check valve at the top, to avoid downtime caused by water damage to the unit.
4, the upper part of the submersible motor shaft with a labyrinth of sand and two reverse assembly of the oil seal to prevent the flow of sand into the motor.
5, submersible motor with water-lubricated bearings, the lower part with rubber pressure regulating film, pressure regulating spring, composed of surge chamber, regulating the temperature changes caused by the pressure; motor winding with polyethylene insulation, nylon sheath durable consumer goods water magnet wire , Cable connection by QJ-type cable connector technology, the joint insulation off scratch paint layer, were connected, welding firm, with a layer of raw rubber around. And then wrapped with 2 to 3 layers of waterproof adhesive tape, wrapped with 2 to 3 layers of waterproof adhesive tape or a layer of rubber tape wrapped with water (bike belt) to prevent seepage.
6, the motor is closed, the use of precision only bolts, cable exports plus pads for sealing.
7, the motor has a water injection hole at the top, there is a vent, the lower part of a drainage hole.
8, the motor is equipped with the upper and lower thrust bearing on the bottom, thrust bearing groove for cooling, and it is the stainless steel thrust plate, with the pump up and down the axial force.
Brand certification Weihu pump safety deep well submersible pump
Deep well submersible pump is an important product of mineral industry, animal husbandry and agriculture in China. In particular, the use of deep well submersible pumps in agriculture and animal husbandry should pay particular attention to power problems. Rural areas as a result of low-voltage power supply line is relatively long, the end of the line voltage is too low is common. When the phase voltage is below 198 volts, the line voltage is lower than 342 volts, submersible pump motor speed down, when less than 70% of the rated speed, start the centrifugal switch will be closed, resulting in long start-up winding power and even burn Windings and capacitors. Conversely, a high voltage causes the motor to overheat and burn out the winding. Therefore, the submersible pump in operation, the operator must always observe the power supply voltage value, if less than 10% of the rated voltage, higher than 10% of rated voltage above, the motor should stop running, find out the cause and troubleshooting.
Leakage protection device, also known as protectors, its role from the "security device" the three words can be understood. Wei Shanghai pump brand submersible pump has a number of patents, leakage protection is the days of submersible pump submersible pump R & D and production of one of the important projects. Combined with years of market feedback from users under the premise of large data, Wei-hu pump is deep digging the user pain points, increased R & D funds, through continuous experiments to determine the safety of the product. Because the deep well submersible pumps are mostly in the water, easy to leakage caused by power loss and even lead to electric shock accident, equipped with leakage protection deep well submersible pump, as long as the submersible pump leakage value exceeds leakage protection action current value (generally not more than 30 mA), leakage protection device will cut off the power of the submersible pump to avoid leakage of waste of electricity to ensure safety. It is also on this basis, Wei Hu pump produced by the deep well before each submersible pump factory will automatically control the test stand insulation resistance data monitoring to increase the safety of the pump and the use of more. "Never leave troubles" has also been the heart of Shanghai Wei people to product quality strictly to control the best interpretation.
Leakage protection device, also known as protectors, its role from the "security device" the three words can be understood. Wei Shanghai pump brand submersible pump has a number of patents, leakage protection is the days of submersible pump submersible pump R & D and production of one of the important projects. Combined with years of market feedback from users under the premise of large data, Wei-hu pump is deep digging the user pain points, increased R & D funds, through continuous experiments to determine the safety of the product. Because the deep well submersible pumps are mostly in the water, easy to leakage caused by power loss and even lead to electric shock accident, equipped with leakage protection deep well submersible pump, as long as the submersible pump leakage value exceeds leakage protection action current value (generally not more than 30 mA), leakage protection device will cut off the power of the submersible pump to avoid leakage of waste of electricity to ensure safety. It is also on this basis, Wei Hu pump produced by the deep well before each submersible pump factory will automatically control the test stand insulation resistance data monitoring to increase the safety of the pump and the use of more. "Never leave troubles" has also been the heart of Shanghai Wei people to product quality strictly to control the best interpretation.
订阅: