Analysis of fountain pump failure

Fountain pump failure analysis, fountain pump, fountain pump flow is insufficient, the occurrence of cavitation, etc. are hydraulic failure. Pump does not run, overheating of the bearing is a mechanical failure. Under normal circumstances, the two faults exist in a phenomenon, such as the lack of head, pump Diao deep operation there is no abnormal vibration and sound.
Troubleshooting should follow the following principles: with the fault should be promptly excluded, the machine can not make sick work. Troubleshooting should: clarify the performance, analysis of a reason to be eliminated. The cause of the failure should be analyzed in many ways, and strive to accurately determine. Exclusion of specific conditions should be specific treatment, can not be mechanically applied.
Analysis and Solution of Common Fault
1) the pump does not water, usually due to a impeller flow path blocked by debris, 2 pump impeller reverse direction of operation, 3 device head beyond the pump design head range caused. As long as the clean-up impeller flow channel, re-connect the motor power cord and re-select the appropriate pump can solve the problem.
4) bending deformation of the pump shaft. With the dial gauge to measure the o axis of the pump shaft in the radial volume, if it is rolling bearings, usually should not be more than 0.05mm beating, if it is sliding bearings, sliding bearing friction should not exceed the gap. In addition, check the rotation of the shaft and wheel rotation Yi, pump normal operation, at different speeds have different rotation jitter allowed value, usually 1450 r / min allowable value of not more than 0.15mm, 2900 points in time to allow The value is less than or equal to 0.10 mm. If the permissible value is exceeded, the shaft and wheel v are measured circumferentially point by point to see if the wheel 0 is eccentric, or is not concentric, or the shaft is bent. It is also possible that the axis is good for neutrality, the rotation is very large, or there is no rotation Mm, but the pay neutral is poor, should be corrected.
5) There is abnormal vibration and sound when the pump is running. It is usually caused by the poor neutral of pump shaft and motor shaft, bending deformation of pump shaft, cavitation of running and friction of rotating parts. If none of the above problems exists, Feet, pump shell bolts without loosening, check the pump pipe there is a clear stress. If the stress is too great, it should be supported at the inlet or outlet to reduce or eliminate stress. Remove and reinstall if necessary.
2) Lack of head, pump outlet pressure can not meet the needs of working conditions. There are many reasons for this failure: pump cavitation, impeller wear and tear after long-term use, supporting the motor speed is lower than the required pump speed, etc., will lead to lower pump head. Increase the level of the pump inlet level or Yang lk pump installation location, can avoid the occurrence of cavitation. Replacement of the impeller is worn, and select the pump to match the motor, is one of the ways to troubleshoot.
3) bearing overheating, bearing more than the normal temperature range. Generally due to a bearing housing lack of oil or 2 oil deterioration caused by bearing temperature anomalies. In the timely confirmation of the reasons to add grease, update the lubricating oil, so as not to damage the bearings. Second, the cause of bearing overheating and 3 pump shaft, motor shaft is not concentric,

2017年1月15日星期日

Hot water well submersible pump unique structural features

1, hot water well submersible pump heat resistant high temperature submersible motor unique structure
    The high-temperature motor is filled with water and sealed structure, the cavity is filled with water or rust-proof lubricating fluid (rust inhibitor). The joints are sealed with 0-shaped rubber seals or sealant. The shaft end of the motor is equipped with a rubber skeleton oil seal 4 or a single-face mechanical seal 5 so as to prevent the solid impurities and sediment particles in the motor from entering the motor interior. The stator (including windings) 7 of the motor, the rotor 8 and the bearings are all operated in water. The stator winding of the motor is made of water-resistant winding wire with polyethylene insulation, polyethylene insulation or modified polypropylene insulation, and has good water-proof insulation performance and long service life. Water lubricated sliding guide bearings 6 and 9 made of copper alloy, graphite or polymer plastic and the like are attached to the upper and lower portions of the motor, and a water lubricated thrust bearing 11 made of graphite or thermosetting plastic or the like is provided at the lower end of the shaft, In order to withstand the rotor running motor and the axial thrust of the pump. In order to limit the pump to start up the shaft to move up, resulting in short-term motor shaft seal sealing leakage, the lower part of the motor with thrust bearing sliding bearings 10. The bottom of the motor is equipped with rubber pressure regulating bladder 13, to adjust the cavity filled with water due to temperature or pressure changes caused by volume changes. For the thin steel coil shell structure, the shaft end of the installation of rubber skeleton oil seal or mechanical seal for power smaller, shorter core, the chassis force smaller motor. For the steel pipe shell structure, the overall rigidity is better for larger power, longer core, the chassis force larger motor.
2, hot water well submersible pump motor main features
    (1) wells with water-filled hot water submersible motor structure is simple, stator and rotor windings and core immersed in water, cooling effect, the output power, high efficiency.
    (2) due to water-filled high-temperature motor cavity filled with water, the use of the process of leakage on the installation of the well water quality will not produce pollution.
    (3) water-filled high-temperature motor stator windings, iron and bearings are working in the water, the stator winding wire used and its processing technology, joint materials and dressing process, water lubrication bearing structure, materials and processing technology, Iron and metal materials, anti-rust anti-corrosion treatment have high requirements.
    (4) water-filled motor has sufficient reliability, is the well with hot water submersible motors in the production of the most, the most widely used one.

2017年1月12日星期四

Identification of quality problems of hot water submersible pump several cases

Case 1:
  Due to failure to install according to the instructions required to fill the clean water and clean liquid, or did not put the steam hole open, resulting in false water level. Resulting in hot water submersible pump motor winding burned by the responsibility of the use or installation unit to be responsible.
  The phenomenon is: water invaded the location of the winding adhesion to one (the degree of adhesion can not help the same)
Case 2:
  Because the unit long-term unattended, there is no periodic clean wipe repair the circuit nodes, resulting in increased resistance wire blown fuse, protective measures to adjust and inappropriate or relay failure, resulting in phase loss, the responsibility of the burned winding by the user.
  Phenomenon: a hot water submersible pump unit can not start work, the motor insulation is zero. (If the motor power is large, the scene does not have to open the conditions, must return to the factory identification, the user can be assigned to participate in the identification of technical staff) Winding connection If there is a delta connection of which a winding Burned, the stars connected to the two-phase winding burned, which can be identified as lack of burned. Responsibility for this situation by the use of units to be responsible.
Case 3:
  The user according to the "instructions" requirements, in the one-year warranty period, after the open is due to mechanical wear and tear caused by motor damage, but because of the user's protective measures are sensitive, winding does not burn can continue to use, the factory is responsible for free maintenance Or replacement of mechanical parts, if the hot water submersible pump motor failure caused by mechanical failure of the winding, the user's protective measures do not work, the factory responsible for the maintenance but the cost of the burden of half of the maintenance.
Case 4:
  Hot water submersible pump motor rotor Broken shaft: rotor shaft and rotor silicon steel from: stator casing welding cracking: motor fastening screws loose, are manufacturing quality problems, the responsibility of the mountain manufacturer is responsible for. The solution is: manufacturers responsible for the replacement of new hot water submersible pumps and motors. (Note: the manufacturer is responsible for the replacement of the unit itself is not responsible for associated losses)
  Hot water submersible pump quality problem definition _ mainly from the material and performance of the hot water submersible pump quality requirements of the high hope of using a long life point, we should pay more attention to his material, like the stator height, silicon steel quality Cold rolling is better than cold rolling), the rotor shaft (good with stainless steel welding), as well as oil seals, which is very important for home use if the use of silicon carbide on the very good , Bearing is also very important, even if the brand is a human bearing, which is also divided into 369 and so on. You say the submersible pump, a relatively broad scope, at least talk about how much power, use of such information. Performance, then, you take the pump to test, look at his output power, head flow, speed load how, the same level of motor, high speed, light load.

Hot water submersible pump motor performance and features introduced

Hot water submersible pump motor is mainly submerged in water-based motor; will be installed within the lightning protection device, * thermal protection, * using electronic starter.
① no centrifugal switch, no capacitance, to avoid mechanical wear and tear, increase the number of starts, reduce the volume.
② stator outer stainless steel welding, with stainless steel lining, filled with epoxy resin sealed. Sealing performance, corrosion resistance, heat fast, anti-deep-water pressure, long life and reduce costs.
③ fully enclosed squirrel cage rotor, high-quality copper tank, before and after the copper-ring welding, not easily deformed or broken, conductive properties, and high efficiency. Steel by chemical treatment does not rot.
④ With thrust bearings, can carry a greater axial load, said by the Fen Shuo said stone attack Ru field maintenance.
⑤ motor by the water lubrication, internal and external water cooling, the use of water environment to avoid pollution. Normal working dive depth of up to 900 meters, to solve the domestic deep-water operations and scientific research problems.
* Refers to the single-phase two-wire motor is equipped.
  For proper installation, please read the instruction manual carefully before use. Power and fittings must be installed in accordance with local and international codes. All metal fittings and hot water submersible pump motors should be grounded. All ground cables shall be not less than the specifications of the motor cables. External power cord to be greater than the motor, seven sources lead wire, then the product must be absolutely sealed. Be sure to use within the rated voltage range, if the voltage high and low, hot water submersible pump motor will not work. To reduce the risk of electric shock, do not connect the power cord during use or in the water. Do not use the submersible pump in the swimming area.

Hot water submersible pump operation and maintenance and storage

Hot water submersible pump operation and maintenance and storage is very important, but also an excellent way to extend the service life, six months of normal operation suddenly a problem, said the quality of hot water submersible pump not, most of the time we ignore the very small The details, we share the following to maintain a small hot water submersible pump details.
1, Hot water submersible pump operation and maintenance:
(1) hot water submersible pumps should be used within the specified range, hot water submersible pump flow must not be too large. When the scope beyond the provisions, likely to cause hot water submersible pump rotor channeling, ammeter swing, the longer the work will result in a serious pump for bad, on the contrary, the pump flow and not too small, otherwise it will increase the downward axial force, So that the life of the entire unit affected.
(2) 8 hours in operation should be fully checked once, ammeter and gauge instructions are significant changes in the operation, whether there is a voice, the normal working current should not be greater than the motor nameplate on the specified rating.
(3) the operation should always check the safety protection device instrumentation reliability and correctness.
2,Hot water submersible pump overhaul:
   One of the following conditions should be shut down for maintenance:
(1) hot water submersible pump running in the steady operating point, while the current exceeds the specified value or a sudden reduction in traffic.
(2) Insulation resistance is low (in the case of thermal state should not be less than 0.5MΩ).
(3) the unit in the operation of abnormal noise or vibration.
(4) power supply voltage and frequency are not up to the requirements.
3,Hot water submersible pump storage:
(1) hot water submersible pump should be stored within the storage of water, the surface wipe, coated with anti-rust oil.
(2) for the long-term suspension of hot water submersible pumps, to professional and technical personnel under the guidance of open, naturally dry, with the parts coated with rust oil, non-coated with anti-rust paint parts.
(3) Within one week after hanging out the well, the unit should go into the well, unscrew the water hole and water hole of the motor, and put the water into the net.
(4) such as in the winter, hot water submerged pump hanging out of the well is still down to use, release the internal storage of water, storage location overflow of not less than 0 ℃, to prevent residual water within the body to freeze

Application of electrostatic paint coating for pump subassembly of hot water submersible pump

Geothermal well _ hot springs use hot water submersible pump to enhance the water, then most of the water quality of hot water wells have different degrees of corrosive and a small amount of sediment; simply spray paint in the unit table, and can not effectively prevent the pump body Corrosion of wear-resistant materials, the unit cost is relatively high, stainless steel material _ duplex steel _ copper material for hot water wells to enhance the application of water is not a lot, mainly should be For the price of the problem.
Now to share with you the Shanghai Wei Shanghai pump pump components introduced electrostatic coating the advantages of coating treatment:
① excellent chemical resistance.
② excellent corrosion resistance:
Electrostatic paint coating can withstand sewage and a variety of water treatment agents (some of which will also produce corrosion of stainless steel)
● Concentrated brine.
● Sewage: urea, ammonia, hydrocarbons, sodium acetate, fatty acid Moet.
● eliminate agent: nitrogen, nitrogen, ozone.
● oxidant: oxygen, from potassium permanganate.
● flocculants and softeners: ferric chloride, aluminum chloride, sulfate.
③ excellent wear resistance.
④ excellent impact resistance.
⑤ excellent resistance to bending.
⑥ excellent weathering performance.
⑦ excellent resistance to cavitation performance.
⑧ excellent edge of the enclosed performance.
Electrostatic paint coating processing advantages:
● easy to control powder adhesion;
● can achieve partial coating;
- the coating can be melted in an oven at a lower temperature and for a shorter period of time than the preheating step of the fluidized bed;
• No cross-linking risk compared to thermosetting materials;
● the required amount of powder is small;
● Coating automation can be achieved.
 Electrostatic paint coating treatment is mainly used in hot water submersible pump body: the fluid flow shell on the impeller, the effective avoid some unnecessary wear and tear corrosion agent. Several years of application by the customer's unanimous approval