General rules for engineering investigation of water (ground) source hot water well submersible pump system

As a pillar product series of Shanghai Weihu pump, water (ground) source hot water well submersible pump has been used for many years in design, manufacture and practical application. It continuously breaks through the high heat-resisting technology of submersible pump, In the more stable and durable.
  General rules for engineering investigation of design of water (ground) source hot water submersible pump system.
  The condition of the engineering site and the conditions of the shallow geothermal energy resource are the foundation of the application of the ground source heat pump system. Ground source hot water submersible pump system design, should be based on investigation and investigation, select the use of buried pipes, ground water or surface water source heat pump system. The shallow geothermal energy resources investigation includes the underground pipe heat exchange system investigation, the groundwater heat exchange system survey and the surface water heat exchange system survey.
  In the area of ​​the project area or in the vicinity of wells, the existing engineering survey and well data can be investigated and collected. The radius of the survey area should be greater than the proposed heat exchange area of ​​100 to 200m. Type, structure, depth, stratigraphic section, water volume, water level, water temperature and water quality, but also should understand the use of wells, mining methods, the use of the well, Annual water consumption and water level changes and so on.
  The usable area of ​​the project site shall meet the requirements of the construction of surface water pumping structures (surface water heat exchange systems) or the construction of groundwater pumping wells and recharge wells (groundwater heat exchange systems) or the laying of horizontal or vertical ground heat exchangers Heat transfer system) needs. At the same time should meet the placement and operation of construction equipment and the need to lay outdoor pipe network.
  Water (ground) source of hot water submersible pump system design must be technologically advanced, economical and reasonable, safe to use.
  Some of the survey, have good use value, water (ground) source of hot water submersible pump to play it with a large role in water (ground) source hot water submersible pump pumping Tianjin Auto Pump, your trust is that we continue The pursuit of high-quality, high-performance power source.

Hot water well submersible pump orders should pay attention to what technical requirements

Hot water well submersible pump the most troublesome problem is the cavitation, the key is the choice of NPSH, plus cooling device is better, in addition to media, flow, temperature, there are pump head, especially the NPSH Requirements, because the hot water is easy to produce cavitation, using a mechanical seal or packing seal, the motor is an ordinary motor or household shape motor or explosion-proof motor, the pump seal is required to bring cooling water.
Should be concerned:
1, the implementation of the standard pump.
2, the pump NPSH.
3, the use of mechanical seals or packing seal, if the need for mechanical seal quench.
4, whether the need for cooling bearings.
5, the structure of the pump type.
6, the pump material

Guide to the start - up, operation and maintenance of hot water well submersible pump

Temperature well with submersible pumps, also known as hot water well submersible pumps (hot water deep well pump) in the course of the operation is often due to improper operation, out of this kind of problem, today we hot water submersible pump start-up, operation and maintenance to do some simple guidance , So as not to use the process of the problem.
  Hot water submersible pump start:
  1, the motor is full voltage direct start, should be checked before starting.
  (1) the control circuit wiring is correct and reliable, the protection device is safe and effective.
  (2) the water pump gate valve should not be closed, at least to open to 1/4 to 1/6.
  2, all ready, you can close, start the motor, start within one minute after the gate valve should be adjusted immediately to the normal operation of the required degree of opening.
  3, the motor to start again, the second start should be 10 minutes after the stop, when the need for a third start, the interval of 1 to 2 hours.
  Hot water submersible pump operation and maintenance:
  1, hot water pump should be light after the arrival of light transport, careful disassembly, do not allow the cable to drag the unit.
  2, hot water pump after arrival. For a period of time to install, you should do a good job storage work to prevent dirt into the motor internal.
  3, start the motor, observe the ammeter, voltmeter action and data is normal, whether the three-phase current balance, pump running is smooth, with or without noise or vibration.
  4, running, must be observed every 15 minutes, voltage, current value, three-phase current shall not exceed 1.05 times the rated current value, if more than immediately stop the inspection and repair.
  5. When running, the water temperature monitoring device on the switch control cabinet measures the water temperature at the end of the motor winding. When the temperature measuring device indicates the temperature exceeds the above temperature, the monitoring device should act. When the monitoring device malfunctions, the motor should be cut off.
  6, the insulation resistance measured once a week, each measurement results compared with the previous, if found to gradually reduce or decrease a lot, we must take measures to lift the pump check to avoid short circuit, burn the motor winding, insulation resistance, such as Not less than 10 MΩ can continue to run.
  7, hot water pump In the proper use and storage of the case, the Tianjin Auto Pump three guarantees according to the contract.
  The northern winter approaching, geothermal heating work began, the purchase of hot water submersible pump purchase has been included in the schedule to buy geothermal wells with submersible pump to hold on to consider Tianjin Auto Pump, the strength of technology, practical experience, geothermal wells with diving Pump quality assurance 2 more than the heating period, the quality of self-evident.

Hot water well submersible pumps for water quality of mineralization and water quality requirements

QJR series of hot water well submersible pumps for water (ground) source of hot wells and hot pools, etc., for the extraction of geothermal water, hot water recycling, heat cycle. Geothermal is a natural form of cutting cheap, clean green energy, is widely used for mining (for) warm, medical, spa bathing, breeding, planting, industrial and agricultural production, entertainment services and so on. ATQJR series hot water well submersible pump submerges into geothermal well / high temperature water. It has the advantages of heat resistance, corrosion resistance, high efficiency, energy saving, green environmental protection, convenient installation and maintenance, and is a tool for geothermal development and geothermal utilization.

Hot water well submersible pump water quality and water quality have certain requirements:
 ① salinity ≤ 4000;
 ② chloride ion ≤ 600;
 ③ sulfuric acid with ≤ 1000;
 ④ Ammonium ion ≤ 1.0;
 ⑤ fluoride ion ≤ 4.0;
 ⑥ pH (pH) 6.5-8.5, corrosion-resistant hot water submersible pump: 4-10;
 ⑦ hydrogen sulfide ≤ 1.0;
 ⑧ corrosive carbon dioxide ≤ 2.5;
 ⑨ dissolved oxygen ≤ 2.5;
 ⑩ solid content (weight ratio) ≤ 0.01%.

 Different water quality and chemical composition of the more complex water quality can choose the corresponding use of hot water submersible pump; such as: 304,316,316 L, bronze, duplex steel and other high corrosion-resistant materials, reduce our human and material resources unnecessary investment , The external factors will not be reduced to a minimum; Tianjin Auto Pump can provide different degrees of heat, different degrees of decay of the wells with hot water submersible pumps for a variety of complex water environment.
  
  Well with hot water submersible pump models are: [water temperature: 40-80 ℃, 80-100 ℃, 100-125 ℃]
  ① AT150QJR-flow: 5-50
  ② AT200QJR-flow: 10-100
  ③ AT250QJR-flow: 32-200
  ④ AT300QJR-flow: 160-400
  ⑤ AT350QJR-flow: 300-450
  ⑥ AT400QJR-flow: 300-630
  ⑦ AT500QJR-flow: 500-100
  Professional hot water well submersible pump manufacturer, preferred Tianjin Auto Pump, not the same quality, more peace of mind to use.

The requirements of ground source hot water well submersible pump motor

Ground source  hot water well submersible pump motor shall comply with the provisions of GB/T2818-2014. The design and construction of the motor, it must be with hot water pump operating conditions (such as frequency and frequency conversion, 380 v and 6000 v, etc.) and maintenance requirements. Motor shall be the new type of high efficiency and energy saving motor (not the first, second and third batch out) the directory products, motor adopts three-phase 50 hz, rated voltage 380 v ac motor.
Hot water well submersible pump motor drag equipment nameplate output of not less than 115% of the required output. For rated voltage is 400 v, 50 hz frequency motor, when the frequency is rated, and the power supply voltage and rating of the deviation of not more than plus or minus 10%, the motor should be able to output rated power, voltage when rated, and the power frequency and rating the deviation of not more than plus or minus 5%, the motor should be able to output power rating. Cold starting of the motor allows 2 times, each time interval for 5 minutes. Hot starting allow one time, starting time, such as no more than 2 ~ 3 seconds, can start many times.
Ground source heat pump well matching motor is suitable for all voltage starting, to ensure that the motor under the under voltage automatic starting, allowing high voltage motor automatic starting voltage is 65% ~ 70% of the rated voltage, low voltage from the starting voltage is 55% ~ 60% of the rated voltage. To quickly switch motor should be able to afford the power loss in the process of electricity without being damaged, and assume that the motor is full load running in front of the switch. The damage of the motor torque is not less than 180% of the full load torque. Multiple motor starting current is not more than six times the rated current. Under the rated voltage, maximum torque to the guarantee of the ratio of the rated torque value is 1.6 times.
Well ground source  hot water well submersible pump motor cable and wiring requirements: requires electrical outlet for line 6 (three-phase line from in single-phase motor is divided into 2 to 6 lines drawn into two three-phase joint, there are two outlet hole to the outside of motor, by 2 three cable connect to inoue, to reduce the diameter of cables and connectors, prevent wall scratch). The cable can meet the requirements of motor power.
Ground source heat pump well matching motor should be confined water filling type, protection grade by 8, factory over 150 M Ω insulation resistance.
Heat pump is fitted motivation should be by the bidder according to complete sets of experience with mature and the performance of the product, and in accordance with the current effective version of the rotating machine - norm and performance standards. Bidder shall ensure that the whole equipment meet the requirements of technical specification book.

2017年1月6日星期五

The advantages of stainless steel submersible pump

The advantages of stainless steel submersible pumps
Displacement adaptability. The volume of the pump is controlled by the amount of eccentricity of the eccentric end cover. Therefore, it is possible to change the volume of the pump by changing the eccentricity with different eccentricity Eccentric end cap, to adjust the pump's original displacement range. Therefore, for the field use of the pump, if the fluid volume in a range of changes, the existing speed adjustment can not adapt to the change, you can only replace the eccentric end cap to adapt to the new flow range, Without the need to replace the new pump, so you can simplify the site operation, reducing the replacement of the entire pump on the impact of production.
Compact size is another feature of the pump. Because of the structure optimization of the pump, its volume is only 1/41/3 of that of the conventional pump, so it is convenient for users to manage and maintain it.
Low maintenance costs Because the pump drive system is simple, can take a simple belt drive, the stainless steel pump failure rate of the entire system is very low, and maintenance is very simple, which can reduce maintenance and repair costs for the user. Suitable for a variety of media The pump to remove the backflow, self-lubricating device, but also can be used as a waste oil, heavy oil pump, and no specific requirements for sand content, transmission medium, the maximum sand diameter up to 5mm, medium viscosity 150Pas.